SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Huckins JN, Petty JD, Booij K. 2006. Monitors of Organic Chemicals in the Environment—Semipermeable Membrane Devices. Springer, New York, NY, USA.
  • 2
    Petty JD, Huckins JN, Zajicek JF. 1993. Application of semipermeable membrane devices (SPMDs) as passive air samplers. Chemosphere 27: 16091624.
  • 3
    Adams RG, Lohmann R, Fernandez LA, MacFarlane JK, Gschwend PM. 2007. Polyethylene devices: Passive samplers for measuring dissolved hydrophobic organic compounds in aquatic environments. Environ Sci Technol 41: 13171323.
  • 4
    Rusina TP, Smedes F, Klanova J, Booij K, Holoubek I. 2007. Polymer selection for passive sampling: A comparison of critical properties. Chemosphere 68: 13441351.
  • 5
    Arthur CL, Pawliszyn J. 1990. Solid phase microextraction with thermal desorption using fused silica optical fibres. Anal Chem 62: 21452148.
  • 6
    Harner T, Farrar NJ, Shoeib M, Jones KC, Gobas FABC. 2003. Characterisation of polymer-coated glass as a passive air sampler for persistent organic pollutants. Environ Sci Technol 37: 24862493.
  • 7
    Shoeib M, Harner T. 2002. Characterisation and comparison of three passive air samplers for persistent organic pollutants. Environ Sci Technol 36: 41424151.
  • 8
    Booij K, Smedes F, van Weerlee EM. 2002. Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers. Chemosphere 46: 11571161.
  • 9
    Carls MG, Holland LG, Short JW, Heintz RA, Rice SD. 2004. Monitoring polynuclear aromatic hydrocarbons in aqueous environments with passive low-density polyethylene membrane devices. Environ Toxicol Chem 23: 14161424.
  • 10
    Farrar NJ, Prevedouros K, Harner T, Sweetman AJ, Jones KC. 2006. Continental scale passive air sampling of persistent organic pollutants using rapidly equilibrating films (POGs). Environ Pollut 144: 423433.
  • 11
    Tan BLL, Hawker DW, Mueller JF, Leusch FDL, Tremblay LA, Chapman HF. 2007. Comprehensive study of endocrine disrupting compounds using grab and passive samplers at selected wastewater treatment plants in South East Queensland, Australia. Environ Int 3: 654669.
  • 12
    Shaw M, Muller JF. 2005. Preliminary evaluation of the occurrence of herbicides and PAHs in the Wet Tropics region of the Great Barrier Reef. Mar Pollut Bull 51: 876881.
  • 13
    Shaw M, Mueller JF. 2009. Time integrative passive sampling: How well do Chemcatchers integrate fluctuating pollutant concentrations? Environ Sci Technol 43: 14431448.
  • 14
    Bartkow ME, Booij K, Kennedy KE, Mueller JF, Hawker DW. 2005. Passive air sampling theory for semivolatile organic compounds. Chemosphere 60: 170176.
  • 15
    Booij K, Sleiderink HM, Swedes F. 1998. Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards. Environ Toxicol Chem 17: 12361245.
  • 16
    Huckins JN, Petty JD, Lebo JA, Almeida FV, Booij K, Alvarez DA, Cranor WL, Clark RC, Mogensen BB. 2002. Development of permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices. Environ Sci Technol 36: 8591.
  • 17
    Barkow ME, Jones KC, Kennedy KE, Holling N, Hawker DW, Mueller JF. 2006. Evaluation of performance reference compounds in polyethylene-based passive air samplers. Environ Pollut 144: 365370.
  • 18
    Booij K, Hofmanns HE, Fischer CV, van Weerlee EM. 2003. Temperature-dependent uptake rates of nonpolar organic compounds by semipermeable membrane devices and low-density polyethylene membranes. Environ Sci Technol 37: 361366.
  • 19
    Schäfer RB, Paschke A, Liess M. 2008. Aquatic passive sampling of a short-term thiacloprid pulse with the Chemcatcher: Impact of biofouling and use of a diffusion-limiting membrane on the sampling rate. J Cromatogr A 1203: 16.
  • 20
    Chapra SC. 1997. Surface Water Quality Modeling. McGraw-Hill, New York, NY, USA.
  • 21
    Stephens BS, Kapernick A, Eaglesham G, Mueller J. 2005. Aquatic passive sampling of herbicides on naked particle loaded membranes: Accelerated measurement and empirical estimation of kinetic parameters. Environ Sci Technol 39: 88918897.
  • 22
    Huckins JN, Manuweera GK, Petty JD, Mackay D, Lebo JA. 1993. Lipid-containing semipermeable membrane devices for monitoring organic contaminants in water. Environ Sci Technol 27: 24892496.
  • 23
    Gourlay-Francé C, Lorgeoux C, Tusseau-Vuillemin M-H. 2008. Polycyclic aromatic hydrocarbon sampling in wastewaters using semipermeable membrane devices: Accuracy of time-weighted average concentrations of truly dissolved compounds. Chemosphere 73: 11941200.
  • 24
    Gale RW. 1998. Three-compartment model for contaminant accumulation by semipermeable membrane devices. Environ Sci Technol 32: 22922300.