SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Haase A, Frahm J, Hèanicke W, Matthaei D. 1H NMR chemical shift selective (CHESS) imaging. Phys Med Biol 1985; 30: 341344.
  • 2
    Keller PJ, Hunter WW, Jr., Schmalbrock P. Multisection fat-water imaging with chemical shift selective presaturation. Radiology 1987; 164: 539541.
  • 3
    Foster MA, Hutchison JM, Mallard JR, Fuller M. Nuclear magnetic resonance pulse sequence and discrimination of high- and low-fat tissues. Magn Reson Imaging 1984; 2: 187192.
  • 4
    Bydder GM, Young IR. MR imaging: clinical use of the inversion recovery sequence. J Comput Assist Tomogr 1985; 9: 659675.
  • 5
    Rofsky NM, Lee VS, Laub G, et al. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 1999; 212: 876884.
  • 6
    Dixon WT. Simple proton spectroscopic imaging. Radiology 1984; 153: 189194.
  • 7
    Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991; 1: 521530.
  • 8
    Glover GH, Schneider E. Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magn Reson Med 1991; 18: 371383.
  • 9
    Rybicki FJ, Chung T, Reid J, Jaramillo D, Mulkern RV, Ma J. Fast three-point Dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatric musculoskeletal imaging. AJR Am J Roentgenol 2001; 177: 10191023.
  • 10
    Rybicki FJ, Mulkern RV, Robertson RL, Robson CD, Chung T, Ma J. Fast three-point Dixon MR imaging of the retrobulbar space with low-resolution images for phase correction: comparison with fast spin-echo inversion recovery imaging. AJNR Am J Neuroradiol 2001; 22: 17981802.
  • 11
    Ma J, Singh SK, Kumar AJ, Leeds NE, Zhan J. T2-weighted spine imaging with a fast three-point Dixon technique: comparison with chemical shift selective fat suppression. J Magn Reson Imaging 2004; 20: 10251029.
  • 12
    Reeder SB, Wen Z, Yu H, et al. Multicoil Dixon chemical species separation with an iterative least-squares estimation method. Magn Reson Med 2004; 51: 3545.
  • 13
    Paltiel Z, Ban A. Separate water and lipids images obtained by a single scan. In: Proceedings of the 4th Annual Scientific Meeting of the Society of Magnetic Resonance in Medicine, London, England; 1985. p 172.
  • 14
    Patrick J, Haacke E, Hahn J. Separate water and lipids images obtained by a single scan. In: Proceedings of the 4th Annual Scientific Meeting of the Society of Magnetic Resonance in Medicine, London, England; 1985. p 174.
  • 15
    Ahn CB, Lee SY, Nalcioglu O, Cho ZH. Spectroscopic imaging by quadrature modulated echo time shifting. Magn Reson Imaging 1986; 4: 110111.
  • 16
    Hajnal J, Young I. Use of spatial phase distribution models to produce water and fat only images from single echo shifted data sets. In: Proceedings of the 3rd Annual Scientific Meeting of the Society of Magnetic Resonance; 1995. p 650.
  • 17
    Ma J. Multipoint Dixon imaging with reduced time and increased reliability. In: Proceedings of the 6th Annual Meeting of the ISMRM, Sydney, Australia, 1998 (Abstract 622).
  • 18
    Yu H, Reeder SB, McKenzie CA, et al. Single acquisition water-fat separation: feasibility study for dynamic imaging. Magn Reson Med 2006; 55: 413422.
  • 19
    Ma J. Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm. Magn Reson Med 2004; 52: 415419.
  • 20
    Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591603.
  • 21
    Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952962.
  • 22
    Ma J, Son JB, Bankson JA, Stafford RJ, Choi H, Ragan D. A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging. Magn Reson Imaging 2005; 23: 977982.
  • 23
    King KF, Angelos L. SENSE image quality improvement using matrix regularization. In: Proceedings of the 9th Annual Meeting of the ISMRM, Glasgow, Scotland, 2001 (Abstract 1771).
  • 24
    Foo TK, Sawyer AM, Faulkner WH, Mills DG. Inversion in the steady state: contrast optimization and reduced imaging time with fast three-dimensional inversion-recovery-prepared GRE pulse sequences. Radiology 1994; 191: 8590.
  • 25
    Ma J. Multislice and multicoil phase-sensitive inversion-recovery imaging. Magn Reson Med 2005; 53: 904910.
  • 26
    Ma J. Phase-sensitive IR imaging and its application for tissue segmentation. In: Proceedings of the 7th Annual Meeting of the ISMRM, Philadelphia, Pennsylvania, USA, 1999 (Abstract 1652).