Safety of gadolinium-based contrast material in sickle cell disease

Authors

  • Jonathan R. Dillman MD,

    Corresponding author
    1. Department of Radiology, Section of Pediatric Radiology, C.S. Mott Children's Hospital, University of Michigan Health System, Ann Arbor, Michigan, USA
    • University of Michigan Health System, C.S. Mott Children's Hospital/F3503, Department of Radiology, Section of Pediatric Radiology, 1500 E. Medical Center Dr., Ann Arbor, MI 48109-5252
    Search for more papers by this author
  • James H. Ellis MD,

    1. Department of Radiology, Division of Abdominal Imaging, University of Michigan Health System, Ann Arbor, Michigan, USA
    Search for more papers by this author
  • Richard H. Cohan MD,

    1. Department of Radiology, Division of Abdominal Imaging, University of Michigan Health System, Ann Arbor, Michigan, USA
    Search for more papers by this author
  • Elaine M. Caoili MD,

    1. Department of Radiology, Division of Abdominal Imaging, University of Michigan Health System, Ann Arbor, Michigan, USA
    Search for more papers by this author
  • Hero K. Hussain MD,

    1. Department of Radiology, Division of Abdominal Imaging, University of Michigan Health System, Ann Arbor, Michigan, USA
    Search for more papers by this author
  • Andrew D. Campbell MD,

    1. Department of Pediatrics and Communicable Diseases, University of Michigan Health System, Ann Arbor, Michigan, USA
    Search for more papers by this author
  • Peter J. Strouse MD

    1. Department of Radiology, Section of Pediatric Radiology, C.S. Mott Children's Hospital, University of Michigan Health System, Ann Arbor, Michigan, USA
    Search for more papers by this author

Abstract

Purpose:

To assess the safety of intravenously administered gadolinium-based contrast material in sickle cell disease (SCD) patients.

Materials and Methods:

All pediatric and adult SCD patients evaluated by magnetic resonance imaging (MRI) at our institution between January 1995 and July 2009 were identified. The medical records of SCD patients who underwent contrast-enhanced MRI as well as an equal-sized cohort of SCD patients who underwent unenhanced MRI were reviewed for adverse (vaso-occlusive and hemolytic) events within 1 week following imaging.

Results:

Eight (five mild and three moderate) adverse events were documented within 1 week following contrast-enhanced MRI (38 patients and 61 contrast injections), while six (five mild and one moderate) similar events occurred within 1 week following unenhanced MRI (61 patients and 61 unenhanced MRI examinations). This difference in the number of adverse events was not statistically significant (odds ratio = 1.4; 95% confidence interval [CI] 0.4, 5.2). No severe adverse event occurred in either patient cohort.

Conclusion:

Gadolinium-based contrast materials do not appear to be associated with increased risk of vaso-occlusive or hemolytic adverse events when administered to SCD patients. Larger, prospective studies using multiple gadolinium-based contrast materials would be useful to confirm the results of our investigation. J. Magn. Reson. Imaging 2011;. © 2011 Wiley-Liss, Inc.