SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Prince MR. Gadolinium-enhanced MR aortography. Radiology 1994; 191: 155164.
  • 2
    Masaryk TJ, Laub GA, Modic MT, Ross JS, Haacke EM. Carotid-CNS MR flow imaging. Magn Reson Med 1990; 14: 308314.
  • 3
    Laub GA. Time-of-flight method of MRA. Magn Reson Imaging Clin N Am 1995; 3: 391398.
  • 4
    Dumoulin CL, Souza SP, Walker MF, Wagle W. Three-dimensional phase contrast angiography. Magn Reson Med 1989; 9: 139149.
  • 5
    Dumoulin CL, Yucel EK, Vock P, et al. Two- and three-dimensional phase contrast MRA of the abdomen. J Comput Assist Tomogr 1990; 14: 779784.
  • 6
    Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997; 38: 591603.
  • 7
    Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952962.
  • 8
    Buhaescu I, Izzedine H. Gadolinium-induced nephrotoxicity. Int J Clin Pract 2008; 62: 11131118.
  • 9
    Urata J, Miyazaki M, Wada H, Nakaura T, Yamashita Y, Takahashi M. Clinical evaluation of aortic diseases using nonenhanced MRA with ECG-triggered 3D half-Fourier FSE. J Magn Reson Imaging 2001; 14: 113119.
  • 10
    Miyazaki M, Sugiura S, Tateishi F, Wada H, Kassai Y, Abe H. Non-contrast-enhanced MRA using 3D ECG-synchronized half-Fourier fast spin echo. J Magn Reson Imaging 2000; 12: 776783.
  • 11
    Miyazaki M, Ichinose N, Sugiura S, Kassai Y, Kanazawa H, Machida Y. A novel MR angiography technique: swap phase encode extended data (SPEED) acquisition using half-Fourier RARE. J Magn Reson Imaging 1998; 8: 505507.
  • 12
    Miyazaki M, Takai H, Sugiura S, Wada H, Kuwahara R, Urata J. Peripheral MRA: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging. Radiology 2003; 227: 890896.
  • 13
    Ono A, Murase K, Taniguchi T, et al. Deep vein thrombosis using non-contrast-enhanced MR venography with electrocardiographically-gated three-dimensional half-Fourier FSE: preliminary experience. Magn Reson Med 2009; 61: 907917.
  • 14
    Carr HY. Steady-state free precession in nuclear magnetic resonance. Phys Rev 1958; 112: 16931701.
  • 15
    Scheffler K, Lehnhardt S. Principles and applications of balanced SSFP techniques. Eur Radiol 2003; 13: 24092418.
  • 16
    Nishimura DG, Macovski A, Pauly JM, Conolly SM. MRA by selective inversion recovery. Magn Reson Med 1987; 4: 193202.
  • 17
    Edelman RR, Siewert B, Adamis M, Gaa J, Laub G, Wielopolski P. Signal targeting with alternating radiofrequency (STAR) sequences: application to MRA. Magn Reson Med 1994; 31: 233238.
  • 18
    Kanazawa H, Miyazaki M. Time-spatial labeling inversion tag (t-SLIT) using a selective IR-tag on/off pulse in 2D and 3D half-Fourier FSE as arterial spin labeling. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, 2002. (abstract 140).
  • 19
    Stuber M, Bornert P, Spuentrup E, Botnar RM, Manning WJ. Selective three-dimensional visualization of the coronary arterial lumen using arterial spin tagging. Magn Reson Med 2002; 47: 322329.
  • 20
    Yui M, Miyazaki M, Kanazawa H, Okamoto K. Aortic arch to intracranial 3D MRA with t-SLIT 3D-SSFP using a neurovascular-attached QD head SPEEDER coil. In: Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, 2004. (abstract 2121).
  • 21
    Miyazaki M, Lee VS. Non-contrast-enhanced magnetic resonance angiography: state-of-the-art. Radiology 2008; 248: 2043.
  • 22
    Wedeen VJ, Meuli RA, Edelman RR, et al. Projective imaging of pulsatile flow with magnetic resonance. Science 1985; 230: 946948.
  • 23
    Meuli RA, Wedeen VJ, Geller SC, et al. MR gated subtraction angiography: evaluation of lower extremities. Radiology 1986; 159: 411418.
  • 24
    Constable RT, Gore JC. The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med 1992: 28: 924.
  • 25
    Hinks RS, Constable RT. Gradient moment nulling in fast spin echo. Magn Reson Med 1994; 32: 698706.
  • 26
    Kawanami S, Nakamura K, Miyazaki M, Sugiura S, Yamamoto S, Nakata H. Flow-weighted MRI of the Lungs with the ECG-gated half-Fourier FSE technique: evaluation of the effect of the cardiac cycle. Magn Reson Med Sci 2002; 1: 137147.
  • 27
    Suga K, Ogasawara N, Okada M, Tsukuda T, Matsunaga N, Miyazaki M. Lung perfusion impairments in pulmonary embolic and airway obstruction with noncontrast MR imaging. J Appl Physiol 2002; 92: 24392451.
  • 28
    Furudate N, Miyazaki M. FBI-Navi for easy determination of diastolic and systolic triggering phases in non-contrast fresh blood imaging (FBI). In: Proceedings of the 17th Annual Meeting of ISMRM, Toronto, 2008. (abstract 2902).
  • 29
    Urata J, Wada H, Kuwahara R, Miyazaki M, Nishiharu T, Yamashita Y. Evaluation of lower extremity arterial diseases using flow-dephasing spoiler gradient pulses in ECG-triggered 3D half-Fourier FSE: initial experience. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, 2002. (abstract 1750).
  • 30
    Lim RP, Hecht EM, Xu J, et al. 3D Non-gadolinium enhanced ECG-gated MRA of the distal lower extremities: preliminary clinical experience. J Magn Reson Imaging 2008; 28: 181189.
  • 31
    Nakamura K, Miyazaki M, Kuroki K, Yamamoto A, Hiramine A, Admiraal-Behloul F. Non-contrast-enhanced peripheral MRA: technical optimization of flow-spoiled fresh blood imaging for screening peripheral arterial diseases. Magn Reson Med 2011; 65: 595602.
  • 32
    Haneder S, Attenberger UI, Riffel P, Henzler T, Schoenberg SO, Michaely HJ. Magnetic resonance angiography (MRA) of the calf station at 3.0 T: intraindividual comparison of non-enhanced ECG-gated flow-dependent MRA, continuous table movement MRA and time-resolved MRA. Eur Radiol 2011; 21: 14521461.
  • 33
    Gutzeit A, Stutter R. Froehlich JM., et al. ECG-triggered non-contrast-enhanced MR angiography (TRANCE) versus digital subtraction (DSA) in patients with peripheral arterial occlusive disease of the lower extremities. Eur Radiol 2011; 21: 19791987.
  • 34
    Storey P, Atanasova I, Lim RP, Xu J, Chen Q, Lee VS. Tailoring the flow sensitivity of fast spin-echo sequences for non-contrast-enhanced peripheral MRA. Magn Reson Med 2010; 64: 10981108.
  • 35
    Ono A, Murase K, Taniguchi T, et al. Deep vein thrombosis: diagnostic value of non-contrast-enhanced MR venography using electrocardiography-triggered three dimentional half-Fourier FSE. Magn Reson Med 2010; 64: 8897.
  • 36
    Fan Z, Sheehan J, Bi X, Liu X, Carr J, Li D. 3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP. Magn Reson Med 2009; 62: 15231532.
  • 37
    Edelman RR, Sheehan JJ, Dunkle E, Schindler N, Carr J, Koktzoglou I. Quiscent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: technical considerations and clinical feasibility. Magn Reson Med 2010; 63: 951958.
  • 38
    Sheehan JJ, Fan Z, Davarpanah AH, et al. Nonenahnced MR angiography of the hand with flow–sensitive dephasing–prepared balanced SSFP sequence: initial experience with systemic sclerosis. Radiology 2011; 256: 248256.
  • 39
    Wielopolski PA, Adamis M, Prasad P, Gaa J, Edelman R. Breath–hold 3D STAR MR angiography of the renal arteries using segmented echo planar imaging. Magn Reson Med 1995; 33: 432438.
  • 40
    Radermacher J, Chavan A, Bleck J, et al. Use of Doppler ultrasonography to predict the outcome of therapy for renal–artery stenosis. N Engl J Med 2001; 344: 410417.
  • 41
    Olbricht CJ, Paul K, Prokop M, et al. Minimally invasive diagnosis of renal artery stenosis by spiral computed tomography angiography. Kidney Int 1995; 48: 13321337.
  • 42
    Garovic VD, Achauer MA, Kittner T, et al. Comparison of gadodiamide–enhanced MR angiography to intraarterial digital subtraction angiography for evaluation of renal artery stenosis: results of a phase III multicenter trial. J Magn Reson Imaging 2010; 31: 390397.
  • 43
    Spuentrup E, Manning WJ, Bornert P, Kissinger KV, Botnar RM, Stuber M. Renal arteries: navigator-gated balanced fast field-echo projection MRA with aortic spin labeling: initial experience. Radiology 2002; 225: 589596.
  • 44
    Katoh M, Buecker A, Stuber M, Gunther RW, Spuentrup E. Free-breathing renal MRA with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results. Kidney Int 2004; 66: 12721278.
  • 45
    Parienty I, Rostoker G, Jouniaux F, Piotin M, Admiraal-Behloul F, Miyazaki M. Renal artery stenosis evaluation in chronic kidney disease patients: nonenhanced time-spatial labeling inversion-pulse three-dimensional MR angiography with regulated breathing versus DSA. Radiology 2011; 259: 592601.
  • 46
    Wyttenbach R, Braghetti A, Wyss M, et al. Renal artery assessment with nonenhanced steady-state free precession versus contrast-enhanced MR angiography. Radiology 2007; 245: 186195.
  • 47
    Takahashi J, Tsuji Y, Hamada Y, et al. Non-contrast-enhanced renal MRA using time-spatial labeling pulse (t-SLIP) with 3D balanced SSFP. Proceedings of the 15th Annual Meeting of ISMRM,, Berlin, 2007. (abstract 179).
  • 48
    Shonai T, Takahashi T, Ikeguchi H, Miyazaki M, Amano K, Yui M. Improved arterial visibility using STIR fat suppression in non-contrast-enhanced Time-Spatial Labeling Pulse (Time-SLIP) renal MRA. J Magn Reson Imaging 2009; 29: 14711477.
  • 49
    Lanzman RS, Voiculescu A, Walther C, et al. ECG-gated nonenhanced 3D steady-state free precession MR angiography in assessment of transplant renal arteries: comparison with DSA. Radiology 2009; 252: 914921.
  • 50
    Shimada K, Isoda H, Okada T, Kamae et al. Unenhanced MR portography with a half-Fourier fast spin-echo sequence and time-space labeling inversion pulses: preliminary results. AJR Am J Roentgenol 2009; 193: 106112.
  • 51
    Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced hepatic MRA with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results. Eur J Radiol 2009; 70: 111117.
  • 52
    Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced MRA for selective visualization of the hepatic vein and inferior vena cava with true steady-state free-precession sequence and time-spatial labeling inversion pulses: preliminary results. J Magn Reson Imaging 2009; 29: 474479.
  • 53
    Shimada K, Isoda H, Okada T, et al. Non-contrast-enhanced MR portography with time-spatial labeling inversion pulses: comparison of imaging with three-dimensional half-Fourier fast spin-echo and true steady-state free-precession sequences. J Magn Reson Imaging 2009; 29: 11401146.
  • 54
    Ito K, Koike S, Shimizu A, et al. Intraportal Venous Flow Distribution: evaluation with single breath-hold ECG-triggered three-dimensional half-Fourier fast spin-echo MR imaging and a selective inversion-recovery tagging pulse. AJR Am J Roentgenol 2002; 178: 343348.
  • 55
    Tsukuda T, Ito K, Koike S, Sasaki et al. Pre- and postprandial alterations of portal venous flow: evaluation with single breath-hold three-dimensional half-Fourier fast spin-echo MR imaging and a selective inversion recovery tagging pulse. J Magn Reson Imaging 2005; 22: 527533.
  • 56
    Miyazaki M, Isoda h. Non-contrast-enhanced MR angiography of the abdomen. Eur J Radiol 2011 [Epub ahead of print].
  • 57
    Yamada S, Miyazaki M, Kanazawa H, et al. MRI visualization of cerebrospinal fluid movement with spin labeling: preliminary results in normal and pathophysiological conditions. Radiology 2008; 249: 644652.
  • 58
    Ito K, Shimizu A, Tsukada T, et al. Evaluation of intraportal venous flow distribution by unenhanced MR angiography using three-dimensional fast spin-echo with a selective tagging pulse: efficacy of subtraction of tag-on and tag-off images acquired during a single breath-hold. J Magn Reson Imaging 2009; 29: 12241229.
  • 59
    Isogai J, Miyazaki M, Shimada T, et al. Non-contrast MRA of the toes using time-spatial labeling inversion pulse (time-SLIP) and optimization of flow-spoiled gradient pulses for the assessment of foot arteries in flow-spoiled fresh blood imaging (FBI). In: Proceedings of the 16th Annual Meeting of ISMRM, Toronto, 2008. (abstract 2901).
  • 60
    Hori M, Shiraga N, Watanabe Y, et al., Time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material in the brain: initial investigation. J Magn Reson Imaging 2009; 30: 214218.
  • 61
    Akahane M, Sato J, Komatsu S, Watanabe Y, Satake Y, Ohtomo K. Nonenhanced time-resolved MR angiography for the arteriovenous malformation/fistula of the pelvis and the lower extremity. In: Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, 2010. (abstract 3762).
  • 62
    Nakamura K, Yamamoto A, Nagashima R, Haraoka K, Miyazaki M. Non-contrast-enhanced whole-body MR angiography. In: Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, 2010. (abstract 4441).
  • 63
    Vernickel P, Roschmann P, Findeklee C, Ludeke KM, Overweg J, et al. Eight-channel transmit/receive body MRI coil at 3T. Magn Reson Med 2007; 58: 381389.
  • 64
    Sung K, Nayak K. Measurement and characterization of RF nonuniformity over the heart at 3T using body coil transmission. J Magn Reson Imaging 2008; 27: 643648.
  • 65
    Miyazaki M, Yamashita Y, Wheaton A, et al. Noncontrast MRA at 3T. In: Proceedings of the 19th Annual Meeting of ISMRM, Montreal, 2011. (abstract 3349).
  • 66
    Lanzman RS, Kropil P, Schmitt P, et al. Nonenhanced free-breathing ECG-gated steady-state free precession 3D MRA of the renal arteries: comparison between 1.5T and 3T. AJR Am J Roentgenol 2010; 194: 794798.