SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Hites RA. Organic environmental analyses by mass spectrometry. Biotherapy 1998; 11: 77.
  • 2
    Hoch G, Kok B. A mass spectrometric inlet system for sampling gases dissolved in liquid phase. Archives of Biochemistry and Biophysics 1963; 101: 160.
  • 3
    Kotiaho T, Lauritsen FR, Choudhury TK, Cooks RG, Tsao GT. Membrane introduction mass spectrometry. Analytical Chemistry 1991; 63: 875A.
  • 4
    Wong PSH, Cooks RG, Cisper ME, Hemberger PH. On-line, in situ analysis with membrane introduction MS. Environmental Science and Technology 1995; 29: 215A.
  • 5
    Kotiaho T. On-site environmental and in situ process analysis by mass spectrometry. Journal of Mass Spectrometry 1996; 31: 1.
  • 6
    Kotiaho T, Kostiainen R, Ketola RA, Ojala M, Mattila I, Mansikka T. Membrane inlet mass spectrometry (MIMS), in the past and in the future. In Advances in Mass Spectrometry, vol. 14, KarjalainenEJ, HessoAE, JalonenJE, KarjalainenUP (eds). Elsevier Science: Amsterdam, 1998; chapt. 21, 497524.
  • 7
    Johnson RC, Cooks RG, Allen TM, Cisper ME, Hemberger PH. Membrane introduction mass spectrometry: trends and applications. Mass Spectrometry Reviews 2000; 19: 1.
  • 8
    Kotiaho T, Lauritsen FR. Membrane inlet mass spectrometry. In Sample Preparation in Field and Laboratory, PawliszynJ (ed.). Elsevier Science: in press.
  • 9
    Bauer SJ. Membrane introduction mass Spectrometry (MIMS); an old method that is gaining new interest through recent technological advances. Trends in Analytical Chemistry 1995; 14: 202.
  • 10
    European Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption. European Council: Brussels, 1998.
  • 11
    Safe Drinking Water Act. http://www.epa.gov/OGWDW/sdwa/sdwa.html.
  • 12
    Koester CJ, Clement RE. Analysis of drinking water for trace organics. Critical Reviews in Analytical Chemistry 1993; 24: 263.
  • 13
    Crompton TR. In The Analysis of Natural Waters. vol. 2. Direct Preconcentration Techniques. Oxford University Press: Oxford, 1993.
  • 14
    Soniassy R, Sandra P, Schlett C. In Water Analysis, Organic Micropollutants HP Publication 5962-6216E. Hewlett-Packard, 1994; chapt. 1 and 2, 1172.
  • 15
    Poole CF, Schuette SA. Isolation and concentration techniques for capillary column gas chromatographic analysis. Journal of High Resolution Chromatography and Chromatography Communications 1983; 6: 526.
  • 16
    Pankow JF, Rosen ME. Determination of volatile compounds in water by purging directly to a capillary column with whole column cryotrapping. Environmental Science and Technology 1988; 22: 398.
  • 17
    Pankow JF, Ligocki MP, Rosen ME, Isabelle LM, Hart KM. Adsorption/thermal desorption with small cartridges for the determination of trace aqueous semivolatile organic compounds. Analytical Chemistry 1988; 60: 40.
  • 18
    Pankow JF. Technique for removing water from moist headspace and purge gases containing volatile organic compounds. Application in the purge with whole-column cryotrapping (P/WCC) method. Environmental Science and Technology 1991; 25: 123.
  • 19
    Badings HT, de Jong C, Dooper RPM. Automatic system for rapid analysis of volatile compounds by purge-and-cold-trapping/capillarygas chromatography. Journal of High Resolution Chromatography and Chromatography Communications 1985; 8: 755.
  • 20
    Kostiainen R. Effect of operating parameters in purge-and-trap GC–MS of polar and nonpolar organic compounds. Chromatographia 1994; 38: 709.
  • 21
    Penton Z. Optimization of conditions in static headspace GC. Journal of High Resolution Chromatography 1992; 15: 834.
  • 22
    Goosens EC, de Jong D, de Jong GJ, Brinkman UAT. On-line sample treatment–capillary gas chromatography. Chromatographia 1998; 47: 313.
  • 23
    Murray DAJ. Rapid micro extraction procedure for analyses of trace amounts of organic compounds in water by gas chromatography and comparisons with macro extraction methods. Journal of Chromatography 1979; 177: 135.
  • 24
    Liska I. On-line versus off-line solid-phase extraction in the determination of organic contaminants in water; advantages and limitations. Journal of Chromatography A 1993; 655: 163.
  • 25
    Pawliszyn J. New directions in sample preparation for analysis of organic compounds. Trends in Analytical Chemistry 1995; 14: 113.
  • 26
    Grob K. Hyphenated high-performance liquid chromatography–capillary gas chromatography. Journal of Chromatography A 1992; 626: 25.
  • 27
    Westover LB, Tou JC, Mark JH. Novel mass spectrometric sampling device–hollow fiber probe. Analytical Chemistry 1974; 46: 568.
  • 28
    Tetler LW, Watson JM, Kirkbright GF, Elliott M, Walder R, Scrivens JH. Direct monitoring of trace-level organics using membrane inlet mass spectrometry. In British Mass Spectrometry Society 14th Meeting, Edinburgh, September 18–21, 1984.
  • 29
    Brodbelt JS, Cooks RG. An exceedingly simple mass spectrometer interface with application to reaction monitoring and environmental analysis. Analytical Chemistry 1985; 57: 1153.
  • 30
    Langvardt PW, Brzak KA, Kasti PE. Rapid determination of volatile pollutants in aqueous matrices via flow injection mass spectrometry. In Proceedings of the 34th ASMS Annual Conference on Mass Spectrometry and Allied Topics, Cincinnati, OH, June 1986; 195.
  • 31
    Bier ME, Cooks RG. Membrane interface for selective introduction of volatile compounds directly into the ionization chamber of a mass spectrometer. Analytical Chemistry 1987; 59: 597.
  • 32
    LaPack MA, Tou JC, Enke CG. Membrane mass spectrometry for the direct trace analysis of volatile organic compounds in air and water. Analytical Chemistry 1990; 62: 1265.
  • 33
    LaPack MA, Tou JC, Enke CG. Membrane extraction mass spectrometry for the on-line analysis of gas and liquid process streams. Analytical Chemistry 1991; 63: 1631.
  • 34
    Weaver JC, Abrams JH. Use of variable pH interface to a mass spectrometer for the measurement of dissolved organic compounds. Review of Scientific Instruments 1979; 50: 478.
  • 35
    Slivon LE, Bauer MR, Ho JS, Budde WL. Helium-purged hollow fiber membrane mass spectrometer interface for continuous measurement of organic compounds in water. Analytical Chemistry 1991; 63: 1335.
  • 36
    Canham JS, Pacey GE. Flow-injection systems for sample introduction in mass spectrometry. Analytica Chimica Acta 1988; 214: 385.
  • 37
    Canham JS, Pacey GE. Utilization of dual phase gas diffusion FIA with a mass spectrometer as a detector. Analytical Letters 1988; 21: 1619.
  • 38
    Tsai G-J, Austin GD, Sui MJ, Tsao GT, Hayward MJ, Kotiaho T, Cooks RG. Theoretical analysis of probe dynamics in flow injection/membrane introduction mass spectrometry. Analytical Chemistry 1991; 63: 2460.
  • 39
    Lauritsen FR, Choudhory TK, Dejarme LE, Cooks RG. Microporous membrane introduction mass spectrometry with solvent chemical ionization and glow discharge for the direct detection of volatile organic compounds in aqueous solution. Analytica Chimica Acta 1992; 266: 1.
  • 40
    Wong PSH, Cooks RG. Trace level analysis of volatile and semi-volatile organic compounds in water using a membrane/jet separator interfaced to an ion trap mass spectrometer. Analytica Chimica Acta 1995; 310: 387.
  • 41
    Dejarme LE, Bauer SJ, Cooks RG, Lauritsen FR, Kotiaho T, Graf T. Jet separator/membrane introduction mass spectrometry for on-line quantitation of volatile organic compounds in aqueous solutions. Rapid Communications in Mass Spectrometry 1993; 7: 935.
  • 42
    Hemberger PH, Spall WD, Leibman CP, Cannon TM. Non-chromatographic applications of ion trap mass spectrometry. In Proceedings of the 36th ASMS Conference on Mass Spectrometry and Allied Topics. San Francisco, CA, 1988; 638.
  • 43
    Lister AK, Wood KV, Cooks RG, Noon KR. Direct detection of organic compounds in water at parts-per-billion levels using a simple membrane probe and a quadrupole ion trap. Biomedical and Environmental Mass Spectrometry 1989; 18: 1063.
  • 44
    White AJ, Blamire MG, Corlett CA, Grifftihs BW, Martin DM, Spencer SB, Mullock SJ. Development of a portable time-of-flight membrane inlet mass spectrometer for environmental analysis. Review of Scientific Instruments 1998; 69: 565.
  • 45
    Sysoev AA, Sysoev AA, Poteshin SS, Pyatakhin VI, Shchekina IV, Trofimov AS. Direct sampling time-of-flight mass spectrometers for technological analysis. Fresenius' Journal of Analytical Chemistry 1998; 361: 261.
  • 46
    Soni M, Bauer S, Amy JW, Wong P, Cooks RG. Direct determination of organic compounds in water at parts-per-quadrillion levels by membrane introduction mass spectrometry. Analytical Chemistry 1995; 67: 1409.
  • 47
    Mendes MA, Pimpim RS, Kotiaho T, Eberlin MN. A cryotrap membrane introduction mass spectrometry system for analysis of volatile organic compounds in water at the low parts-per-trillion level. Analytical Chemistry 1996; 68: 3502.
  • 48
    Kostiainen R, Kotiaho T, Ketola RA, Virkki V. Purge-and-membrane with ECD. A new screening method for chlorinated aliphatic hydrocarbons. Chromatographia 1995; 41: 34.
  • 49
    Kostiainen R, Kotiaho T, Mattila I, Mansikka T, Ojala M, Ketola RA. Analysis of volatile organic compounds in water and soil samples by purge-and-membrane/mass spectrometry. Analytical Chemistry 1998; 70: 3028.
  • 50
    Johnson RC, Koch K, Cooks RG, Affinity liquid membrane introduction mass spectrometry. Analytica Chimica Acta 1999; 395: 239.
  • 51
    Shoemaker JA, Bellar TA, Eichelberger JW, Budde WL. Determination of polar volatile organic compounds in water by membrate permeate and trap GC–MS. Journal of Chromatographic Science 1993; 31: 279.
  • 52
    Rivlin AA. Sorption technique in membrane inlet mass spectrometry. Rapid Communications in Mass Spectrometry 1995; 9: 397.
  • 53
    Bier ME, Kotiaho T, Cooks RG. Direct insertion membrane probe for selective introduction of organic compounds into a mass spectrometer. Analytica Chimica Acta 1990; 231: 175.
  • 54
    Lauritsen FR. A new membrane inlet for on-line monitoring of dissolved, volatile organic compounds with mass spectrometry. International Journal of Mass Spectrometry and Ion Processes 1990; 95: 259.
  • 55
    Leth M, Lauritsen FR. A fully integrated trap-membrane inlet mass spectrometry system for the measurement of semivolatile organic compounds in aqueous solution. Rapid Communications in Mass Spectrometry 1995; 9: 591.
  • 56
    Lauritsen FR, Ketola RA. Quantitative determination of semivolatile organic compounds in solution using trap-and-release membrane inlet mass spectrometry. Analytical Chemistry 1997; 69: 4917.
  • 57
    Mendes MA, Eberlin MN. Trace level analysis of VOCs and semi-VOCs in aqueous solution using a direct insertion membrane probe and trap and release membrane introduction mass spectrometry. Analyst 2000; 125: 21.
  • 58
    Riter LS, Charles L, Turowski M, Cooks RG. External interface for trap-and-release membrane introduction mass spectrometry applied to the detection of inorganic chloramines and chlorobenzenes in water. Rapid Communications in Mass Spectrometry 2001; 15: 2290.
  • 59
    Ketola RA, Lauritsen FR. Detection of dicarboxylic acids in aqueous samples using membrane inlet mass spectrometry with desorption chemical ionization. Rapid Communications in Mass Spectrometry 1999; 13: 749.
  • 60
    Lauritsen FR, Mendes MA, Aggerholm T. Direct detection of large fat-soluble biomolecules in solution using membrane inlet mass spectrometry and desorption chemical ionization. Analyst 2000; 125: 211.
  • 61
    Lauritsen FR, Rose J. Determination of steroid hormones by membrane inlet mass spectrometry and desorption chemical ionization. Analyst 2000; 125: 1577.
  • 62
    Matz G, Kesners P. Thermal membrane desorption application (TMDA) method for on-line analysis of organics in water by GC–MS. Analusis 1995; 23: M12.
  • 63
    Matz G, Lennemann F. On line monitoring of biotechnological processes by gas chromatographic-mass spectrometric analysis of fermentation suspensions. Journal of Chromatography A 1996; 750: 141.
  • 64
    Overney FL, Enke CG. A mathematical study of sample modulation at a membrane inlet mass spectrometer - potential application in analysis of mixtures. Journal of the American Society of Mass Spectrometry 1996; 7: 93.
  • 65
    Ohorodnik SK, Shaffer RE, Callahan JH, Rose-Pehrsson SL. Mixture analysis using membrane introduction mass spectrometry and multivariate calibration. Analytical Chemistry 1997; 69: 4721.
  • 66
    Ketola RA, Ojala M, Komppa V, Kotiaho T, Juujärvi J, Heikkonen J. A non-linear asymmetric error function-based least mean square approach for the analysis of multicomponent mass spectra measured by membrane inlet mass spectrometry. Rapid Communications in Mass Spectrometry 1999; 13: 654.
  • 67
    Cook KD, Bennett KH, Haddix ML. On-line mass spectrometry: a faster route to process monitoring and control. Industrial and Engineering Chemistry Research 1999; 38: 1192.
  • 68
    Gardner WP, Callahan JH, Girard JE, Shaffer RE. Multivariate mixture analysis using reduced mass resolution-membrane introduction mass spectrometry and variable selection. Proceedings of the SPIE—The International Society for Optical Engineering 1999; 3856: 181.
  • 69
    Gardner WP, Shaffer RE, Girard JE, Callahan JH. Application of quantitative chemometric analysis techniques to direct sampling mass spectrometry. Analytical Chemistry 2001; 73: 596.
  • 70
    Harland BJ, Nicholson PJD, Gillings E. Determination of volatile organic compounds in aqueous systems by membrane inlet mass spectrometry. Water Research 1987; 21: 107.
  • 71
    Harland BJ, Nicholson PJ. Continuous measurement of volatile organic chemicals in natural waters. The Science of the Total Environment 1993; 135: 37.
  • 72
    Virkki V, Ketola RA, Ojala M, Kotiaho T, Komppa V, Grove A, Facchetti S. On-site environmental analysis by membrane inlet mass spectrometry. Analytical Chemistry 1995; 67: 1421.
  • 73
    Kotiaho T, Kostiainen R, Ketola RA, Mansikka T, Mattila I, Komppa V, Honkanen T, Wickström K, Waldvogel J, Pilviö O. Development of a fully automatic membrane inlet mass spectrometric measurement system for on-line industrial waste water monitoring. Process Control and Quality 1998; 11: 71.
  • 74
    Fries DP, Short RT, Langebrake LL, Patten JT, Kerr ML, Kibelka G, Burwell DC, Jalbert JC, In-water field analytical technology: underwater mass spectrometry, mobile robots, and remote intelligence for wide and local area chemical profiling. Field Analytical Chemistry and Technology 2001; 5: 121.
  • 75
    Short RT, Fries DP, Toler SK, Lembke CE, Byrne RH. Development of an underwater mass-spectrometry system for in situ chemical analysis. Measurement Science and Technology 1999; 10: 1195.
  • 76
    Short RT, Fries DP, Kerr ML, Lembke CE, Toler SK, Wenner PG, Byrne RH. Underwater mass spectrometers for in situ chemical analysis of the hydrosphere. Journal of the American Society of Mass Spectrometry 2001; 12: 676.
  • 77
    Constanza J, Davis WM. Rapid detection of volatile organic compounds in the subsurface by membrane introduction into a direct sampling ion-trap mass spectrometer. Field Analytical Chemistry and Technology 2000; 4: 246.
  • 78
    Ketola RA, Virkki VT, Ojala M, Komppa V, Kotiaho T. Comparison of different methods for the determination of volatile organic compounds in water samples. Talanta 1997; 44: 373.
  • 79
    Ojala M, Ketola R, Mansikka T, Kotiaho T, Kostiainen R. Detection of volatile organic sulfur compounds in water by headspace gas chromatography and membrane inlet mass spectrometry. Journal of High Resolution Chromatography 1997; 20: 165.
  • 80
    Ojala M, Ketola RA, Virkki V, Sorsa H, Kotiaho T. Determination of phenolic compounds in water using membrane inlet mass spectrometry. Talanta 1997; 44: 1253.
  • 81
    Shang C, Blatchley III ER, Differentiation and quantification of free chlorine and inorganic chloramines in aqueous solution by MIMS. Environmental Science and Technology 1999; 33: 2218.
  • 82
    Creaser CS, Weston DJ, Wilkins JPG, Yorke CP, Irwin J, Smith B. Determination of benzene in aqueous samples by membrane inlet, solid phase microextraction and purge and trap extraction with isotope dilution gas chromatography/mass spectrometry. Analytical Communications 1999; 36: 383.
  • 83
    Lopez-Avila V, Benedicto J, Prest H, Bauer S. Direct analysis of MTBE in water using automated membrane-introduction mass spectrometry. Spectroscopy 1999; 14: 37.
  • 84
    Choudhury TK, Kotiaho T, Cooks RG. Analysis of acrolein and acrylonitrile in aqueous solution by membrane introduction mass spectrometry. Talanta 1992; 39: 1113.
  • 85
    Choudhury TK, Kotiaho T, Cooks RG. Detection of low molecular weight aldehydes in aqueous solution by membrane introduction mass spectrometry. Talanta 1992; 39: 573.
  • 86
    Dongre AR, Hayward MJ. Characterization of a new membrane interface designed for analytical scale sample introduction into a mass spectrometer. Analytica Chimica Acta 1996; 327: 1.
  • 87
    Alberici RM, Zampronio CG, Poppi RJ, Eberlin MN. Water solubilization of ethanol and BTEX from gasoline: on-line monitoring by membrane introduction mass spectrometry. Analyst 2002; 127: 230.
  • 88
    Alberici R, Sparrapan R, Eberlin MN, Windmöller D, Augusti R. Polyetherimide-silicone: a 10 µm ultrathin composite membrane for faster and more sensitive membrane introduction mass spectrometry analysis. Analytical Communications 1999; 36: 221.
  • 89
    Morgan JS, Bryden WA, Vertes RF, Bauer S. Detection of chemical agents in water by membrane introduction mass spectrometry. Johns Hopkins APL Technical Digest 1999; 20: 381.
  • 90
    Pungor E Jr, Klibanov AM, Cooney CL, Weaver JC. Continuous 2HHO determination on H2O solution by a computer-controlled mass spectrometer. Biomedical Mass Spectrometry 1982; 9: 181.
  • 91
    George JE III, Ward G, Thoma JJ. Cost-effective monitoring for disinfection by-products and other VOCs by membrane introduction mass spectrometry (MIMS). In Proceedings of Water Quality and Technology Conference. 1997; Volume Date 1996; 30/A.
  • 92
    Takahata N, Igarashi G, Sano Y. Continuous monitoring of dissolved gas concentrations in groundwater using a quadrupole mass spectrometer. Applied Geochemistry 1997; 12: 377.
  • 93
    Kana TM, Darkangelo C, Hunt MD, Oldham JB, Bennett GE, Cornwell JC. Membrane inlet mass spectrometer for rapid high-precision determination of N2, O2 and Ar in environmental water samples. Analytical Chemistry 1994; 66: 4166.
  • 94
    Favretto D, Traldi P, Benassi CA, Bettero A. Silicon membrane interface for the direct analysis of Kathon CG in aqueous solutions and cosmetic emulsions. Biological Mass Spectrometry 1991; 20: 669.
  • 95
    Allen TM, Falconer TM, Cisper ME, Borgerding AJ, Wilkerson CW Jr. Real-time analysis of methanol in air and water by membrane introduction mass spectrometry. Analytical Chemistry 2001; 73: 4830.
  • 96
    Fish CL, McEachren IS, Hassett JP. Hollow fiber membrane system for the continuous extraction and concentration of organic compounds from water. In Proceedings of ACS Symposium Series: Pollution Prevention in Industrial Processes, BreenJJ, DellarcoMJ (eds). American Chemical Society: Washington, DC, 1991; 155.
  • 97
    Savickas PJ, LaPack MA, Tou JC. Hollow fiber membrane probes for the in situ mass spectrometric monitoring of nitrogen trichloride formation during wastewater treatment. Analytical Chemistry 1989; 61: 2332.
  • 98
    Bocchini P, Pozzi R, Andalò C, Galletti GC. Experimental upgrades of membrane introduction mass spectrometry for water and air analysis. Analytical Chemistry 2001; 73: 3824.
  • 99
    Bocchini P, Pozzi R, Andalò C, Galletti GC. Membrane inlet mass spectrometry of volatile organohalogen compounds in drinking water. Rapid Communications in Mass Spectrometry 1999; 13: 2049.
  • 100
    Aggerholm T, Lauritsen FR. Direct detection of polyaromatic hydrocarbons, estrogenic compounds and pesticides in water using desorption chemical ionisation membrane inlet mass spectrometry. Rapid Communications in Mass Spectrometry 2001; 15: 1826.
  • 101
    Sturaro A, Doretti L, Parvoli G, Cecchinato F, Frison G, Traldi P. Direct analysis of organics contained in aqueous solutions by membrane interface: a dedicated electron impact ion source. Biomedical and Environmental Mass Spectrometry 1989; 18: 707.
  • 102
    Alberici RM, Sparrapan R, Jardim WF, Eberlin MN. Selective trace level analysis of phenolic compounds in water by flow injection analysis - membrane introduction mass spectrometry. Environmental Science and Technology 2001; 35: 2084.
  • 103
    Ojala M, Ketola RA, Mansikka T, Kotiaho T, Kostiainen R. Determination of mono- and sesquiterpenes in water samples by membrane inlet mass spectrometry and static headspace gas chromatography. Talanta 1999; 49: 179.
  • 104
    Chang CC, Her GR. On-line monitoring trihalomethanes in chlorinated water by membrane introduction-fast gas chromatography mass spectrometry. Journal of Chromatography 2000; 893: 169.
  • 105
    Lopez-Avila V, Benedicto J, Prest H, Bauer S. Automated MIMS for direct analysis of organic compounds in water. American Laboratory 1999; 31: 32.
  • 106
    Bauer SJ, Cooks RG. Performance of an ion trap mass spectrometer modified to accept a direct insertion membrane probe in analysis of low level pollutants in water. Talanta 1993; 40: 1031.
  • 107
    Bauer S, Solyom D. Determination of volatile organic compounds at the parts per trillion level in complex aqueous matrices using membrane introduction mass spectrometry. Analytical Chemistry 1994; 66: 4422.
  • 108
    Kephart LA, Dulak JG, Slippy GA, Dheandhanoo S. On-line analysis of liquid streams using a membrane interface and a quadrupole mass spectrometer. In Proceedings of ACS Symposium Series: Pollution Prevention in Industrial Processes, BreenJJ, DellarcoMJ (eds). American Chemical Society: Washington, DC, 1991; 178.
  • 109
    Kasthurikrishnan N, Cooks RG. On-line flow injection analysis of volatile organic compounds in seawater by membrane introduction mass spectrometry. Talanta 1995; 42: 1325.
  • 110
    Dheandhanoo S, Dulak J. The application of a membrane interface to on-line mass spectrometric measurements of volatile compounds in aqueous solutions. Rapid Communications in Mass Spectrometry 1989; 3: 175.
  • 111
    Juliano VF, Gozzo FC, Eberlin MN, Kascheres C, do Lago CL. Fast multidimensional (3D and 4D) MS2 and MS3 scans in a high-transmission pentaquadrupole mass spectrometer. Analytical Chemistry 1996; 68: 1328.
  • 112
    Creaser CS, Stygall JW. Membrane introduction-ion trap mass spectrometry for the determination of volatile organics in aqueous effluents. Analytical Proceedings and Analytical Communications 1995; 32: 7.
  • 113
    Sharara K, Mansouri J, Fane AG, Crisp PT, Calderon P, Guilhaus M. Development of membrane introduction mass spectrometry for monitoring trace organics in water. Water Science and Technology 2000; 41: 373.
  • 114
    Gregori AM, Kephart LA. Membrane inlet mass spectrometers used for the on-line analysis of liquid streams. Advanced Instrumental Control 1996; 50: 1179.
  • 115
    Wenhu D, Kuangnan C, Jianli L, Zhenying D. Determination of trace volatile organic compounds in water samples by membrane introduction mass spectrometry. Mass Spectroscopy 1987; 35: 122.
  • 116
    Harland BJ, Nicholson PJ, Finn B. Field measurement of volatile organic chemicals by membrane inlet mass spectrometry. In Proceedings of the 6th European symposium on Organic Micropollutants in the Aquatic Environment, Lisbon 1990, AngelettiG, BjørsethA (eds). Kluwer Academic Publishers: Dordrecht, 1991; 354.
  • 117
    Grant R, Khan K. The field monitoring of organic chemicals in natural and waste waters. Gewässerschutz, Wasser, Abwasser 1989; 106: 323.
  • 118
    Hemond HF. A backpack-portable mass spectrometer for measurement of volatile compounds in the environment. Review of Scientific Instruments 1991; 62: 1420.
  • 119
    Creaser CS, Weston DJ, Smith B. In-membrane preconcentration/membrane inlet mass spectrometry of volatile and semivolatile organic compounds. Analytical Chemistry 2000; 72: 2730.
  • 120
    Nogueira RFP, Alberici RM, Mendes MA, Jardim WF, Eberlin MN. Photocatalytic degradation of phenol and trichloroethylene: on-line and real-time monitoring via membrane introduction mass spectrometry. Industrial and Engineering Chemistry Research 1999; 38: 1754.
  • 121
    Allen TM, Cisper ME, Hemberger PH, Wilkerson CW Jr. Simultaneous detection of VOCs, SVOCs, and organometallic compounds in both air and water matrices using membrane introduction mass spectrometry. International Journal of Mass Spectrometry 2001; 212: 197.
  • 122
    Hampton CV, Person WR, Harvey TM, Updegrove WS, Marano RS. Hydrocarbon gases emitted from vehicles on the road. 1. Qualitative gas-chromatography mass-spectrometry survey. Environmental Science and Technology 1982; 16: 287.
  • 123
    Patnaik P. Handbook of Environmental Analysis: Chemical Pollutants in Air, Water, Soil, and Solid Wastes. CRC Press: Boca Raton, FL.
  • 124
    Dewulf J, Van Langenhove H. Analytical techniques for the determination and measurement data of 7 chlorinated C1- and C2-hydrocarbons and 6 monocyclic aromatic hydrocarbons in remote air masses: an overview. Atmospheric Environment 1997; 31: 3291.
  • 125
    Dewulf J, Van Langenhove H. Anthropogenic volatile organic compounds in ambient air and natural waters: a review on recent developments of analytical methodology, performance and interpretation of field measurements. Journal of Chromatography A 1999; 843: 163.
  • 126
    Henry C. Taking the show on the road: portable GC and GC/MS. Analytical Chemistry 1997; 69: A195.
  • 127
    Wise MB, Thompson CV, Merriweather R, Guerin MR. Review of direct MS analysis of environmental samples. Field Analytical Chemistry and Technology 1997; 1: 251.
  • 128
    Wise MB, Guerin MR. Direct sampling MS for environmental screening. Analytical Chemistry 1997; 69: A26.
  • 129
    Llewellyn PM. Gas inlet system for gas analyzers and gas analyzing system employing same. US Patent 3 421 292, 1969.
  • 130
    Collins GG, Utley D. Simple membrane inlet for direct sampling of organic pollutants in the atmosphere by mass spectrometry. Chemistry and Industry 1972; 2: 84.
  • 131
    Cisper ME, Gill CG, Townsend LE, Hemberger PH. On-line detection of volatile organic compounds in air at parts-per-trillion levels by membrane introduction mass spectrometry. Analytical Chemistry 1995; 67: 1413.
  • 132
    Cooks RG, Bauer SJ. Analyte separation process and apparatus. US Patent 5 448 062, 1995.
  • 133
    Riter LS, Takáts Z, Charles L, Cooks RG. High surface area membrane introduction mass spectrometry for analysis of volatile and semi-volatile organic compounds in air. Rapid Communications in Mass Spectrometry 2001; 15: 1520.
  • 134
    OSHA Regulations (Standards–29 CFR), Standard Number: 1910.1000TABLEZ-1, Limits for Air Contaminants, Table Z-1. http://www.osha-slc.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9992&p_text_version=FALSE
  • 135
    EPA Method TO-15. Determination of volatile organic compounds (VOCs) in air collected in specially-prepared canisters and analyzed by gas chromatography/mass spectrometry (GC/MS). US Environmental Protection Agency: Research Triangle Park, NC, 1999.
  • 136
    EPA Method TO-17. Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes. US Environmental Protection Agency: Research Triangle Park, NC, 1999.
  • 137
    Gordon SM, Callahan PJ, Kenny DV, Pleil JD. Direct sampling and analysis of volatile organic compounds in air by membrane introduction and glow discharge ion trap mass spectrometry with filtered noise fields. Rapid Communications in Mass Spectrometry 1996; 10: 1038.
  • 138
    Cisper ME, Garrett AW, Cameron D, Hemberger PH. Analysis of polar organic compounds using charge exchange ionization and membrane introduction mass spectrometry. Analytical Chemistry 1996; 68: 2097.
  • 139
    Alexander M, Lindinger W, Boscaini E, Prazeller P. Environmental monitoring using membrane introduction combined with proton-transfer-reaction mass spectrometry (PTR-MS). In Proceedings of the 49th ASMS Conference on Mass Spectrometry and Allied Topics, Chicago IL, June 2001; http://www.inmerge.com/aspfolder/ASMSAbstracts.html.
  • 140
    Ottley TW. A quadrupole system for atmospheric pollution monitoring. Dynamic Mass Spectrometry 1980; 6: 212.
  • 141
    Cameron D, Hemberger PH, Alarid JE, Leibman CP, Williams JD. The effects of air and helium on the performance of the ion trap detector when used for real-time monitoring of some atmospheric pollutants. Journal of the American Society of Mass Spectrometry 1993; 4: 774.
  • 142
    Ketola RA, Grøn C, Lauritsen FR. Temperature-programmed desorption for membrane inlet mass spectrometry. Rapid Communications in Mass Spectrometry 1998; 12: 773.
  • 143
    Munchmeyer W, Walte A, Matz G. Online measurement of polycyclic aromatic hydrocarbons by fast GC/MS. Polycyclic Aromatic Compounds 1996; 9: 299.
  • 144
    Cisper ME, Hemberger PH. The direct analysis of semi-volatile organic compounds by membrane introduction mass spectrometry. Rapid Communications in Mass Spectrometry 1997; 11: 1449.
  • 145
    Riter LS, Takáts Z, Cooks RG. Single-sided membrane introduction mass spectrometry for on-line determination of semi-volatile organic compounds in air. Analyst 2001; 126: 1980.
  • 146
    Ketola RA, Mansikka T, Ojala M, Kotiaho T, Kostiainen R. Analysis of volatile organic sulfur compounds in air by membrane inlet mass spectrometry. Analytical Chemistry 1997; 69: 4536.
  • 147
    Cisper ME, Hemberger PH. Organometallic analysis by membrane introduction mass spectrometry. Rapid Communications in Mass Spectrometry 1997; 11: 1454.
  • 148
    Evans JE, Arnold JT. Monitoring organic vapors. Environmental Science and Technology 1975; 9: 1134.
  • 149
    Meier RW. A field portable mass spectrometer for monitoring organic vapors. American Industrial Hygiene Association Journal 1978; 39: 233.
  • 150
    Colorado A, Barket DJ Jr, Hurst JM, Shepson PB. A fast-response method for determination of atmospheric isoprene using quadrupole ion trap mass spectrometry. Analytical Chemistry 1998; 70: 5129.
  • 151
    Martin RS, Westberg H, Allwine E, Ashman L, Farmer JC, Lamb B. Measurement of isoprene and its atmospheric oxidation products in a central Pennsylvania deciduous forest. Journal of Atmospheric Chemistry 1991; 13: 1.
  • 152
    Matz G, Walte A, Munchmeyer W, Rikeit H-E. Measurement of aromatic compounds in automobile exhaust gases with membrane inlet mass spectrometry equipped with an on-line-probe and an automatic Tenax-sampler. Society of Automotive Engineering [Special Publication] SP-1161 (Engine Emissions and Emissions Measurement) SAE: 1996; 175.
  • 153
    Ketola RA, Ojala M, Sorsa H, Kotiaho T, Kostiainen RK. Development of a membrane inlet mass spectrometric method for analysis of air samples. Analytica Chimica Acta 1997; 349: 359.
  • 154
    Ristoiu D, Cosma C, Voros A, Ristoiu T. Evaluation of the volatile organic contents in aqueous samples by MI-QMS technique. Vacuum 1998; 50: 359.
  • 155
    Wilson HK, Ottley TW. The use of a transportable mass spectrometer for the direct measurement of industrial solvents in breath. Biomedical Mass Spectrometry 1981; 8: 606.
  • 156
    Hobbs JR, Barrington AE, Cline JE. Mass spectrum of dynamite effluent. Journal of Vacuum Science and Technology 1974; 11: 557.
  • 157
    Matz G, Trinks H. Mobile mass spectrometer system for the analysis of organic trace gases. International Journal of Mass Spectrometry and Ion Physics 1982; 43: 79.
  • 158
    Mendoza CA, Frind EO. Advective–dispersive transport of dense organic vapors in the unsaturated zone. 1. Model development. Water Resources and Research 1990; 26: 379.
  • 159
    Voice TC, Kolb B. Static and dynamic headspace analysis of volatile organic compounds in soils. Environmental Science and Technology 1993; 27: 709.
  • 160
    Hewitt AD, Miyares PH, Leggett DC, Jenkins TF. Comparison of analytical methods for determination of volatile organic compounds in soils. Environmental Science and Technology 1992; 26: 1932.
  • 161
    Bellar T, Lichtenberg JJ. Determining volatile organics at microgram-per-liter levels by gas chromatography. Journal of the American Water Works Association 1974; 66: 739.
  • 162
    Benstead J, Lloyd D. Spatial and temporal variations of dissolved gases (CH4, CO2 and O2) in peat cores. Microbial Ecology 1996; 31: 57.
  • 163
    Cartaxana P, Lloyd D. N2, N2O and O2 profiles in a tagus estuary salt marsh. Estuarine, Coastal and Shelf Science 1999; 48: 751.
  • 164
    Cowie G, Lloyd D. Membrane inlet ion trap mass spectrometry for the direct measurement of dissolved gases in ecological samples. Journal of Microbiological Methods 1999; 35: 1.
  • 165
    Kana TM, Sullivan MB, Cornwell JC, Groszkowski KM. Denitrification in estuarine sediments determined by membrane inlet mass spectrometry. Limnology and Oceanography 1998; 43: 334.
  • 166
    Lloyd D, Thomas K, Price D, Oneil B, Oliver K, Williams TN. A membrane-inlet mass spectrometer miniprobe for the direct simultaneous measurement of multiple gas species with spatial resolution of 1 mm. Journal of Microbiological Methods 1996; 25: 145.
  • 167
    Lloyd D, Thomas KL, Hayes A, Hill B, Hales BA, Edwards C, Saunders JR, Ritchie DA, Upton M. Micro-ecology of peat: minimally invasive analysis using confocal laser scanning microscopy, membrane inlet mass spectrometry and PCR amplification of methanogen-specific gene sequences. FEMS Microbiology Ecology 1998; 25: 179.
  • 168
    Thomas KL, Benstead J, Lloyd SH, Lloyd D. Diurnal oscillations of gas production and effluxes (CO2 and H4) in cores from a peat bog. Biological Rhythm Research 1998; 29: 247.
  • 169
    Ojala M, Mattila I, Särme T, Ketola RA, Kotiaho T. A new purge-and-membrane mass spectrometric (PAM-MS) instrument for analysis of volatile organic compounds in soil samples. Analyst 1999; 124: 1421.
  • 170
    Ojala M, Mattila I, Tarkiainen V, Särme T, Ketola RA, Määttänen A, Kostiainen R, Kotiaho T. Purge-and-membrane mass spectrometry, a soil screening method for analysis of VOCs from soil samples. Analytical Chemistry 2001; 73: 3624.
  • 171
    Mendes MA, Sparrapan R, Eberlin MN. Headspace membrane introduction mass spectrometry for trace level analysis of VOCs in soil and other solid matrixes. Analytical Chemistry 2000; 72: 2166.
  • 172
    Lammert SA. 2000; directory of mass spectrometry manufacturers and suppliers. Rapid Communications in Mass Spectrometry 2000; 14: 725.