SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Karas M., Hillenkamp F., Laser Desorption Ionization of Proteins with Molecular Masses Exceeding 10000 Daltons. Analytical Chemistry 1988; 60: 2299.
  • 2
    Fenn J. B., Mann M., Meng C. K., Wong S. F., Whitehouse C. M., Electrospray Ionization for Mass-Spectrometry of Large Biomolecules. Science 1989; 246: 64.
  • 3
    Fenn J. B., Mann M., Meng C. K., Wong S. F., Whitehouse C. M., Electrospray Ionization-Principles and Practice. Mass Spectrometry Reviews 1990; 9: 37.
  • 4
    Takats Z., Wiseman J. M., Gologan B., Cooks R. G., Mass spectrometry sampling under ambient conditions with desorption electrospray ionization. Science 2004; 306: 471.
  • 5
    Laiko V. V., Moyer S. C., Cotter R. J., Atmospheric pressure MALDI/ion trap mass spectrometry. Analytical Chemistry 2000; 72: 5239.
  • 6
    Laiko V. V., Baldwin M. A., Burlingame A. L., Atmospheric pressure matrix assisted laser desorption/ionization mass spectrometry. Analytical Chemistry 2000; 72: 652.
  • 7
    Cody R. B., Laramee J. A., Durst H. D., Versatile new ion source for the analysis of materials in open air under ambient conditions. Analytical Chemistry 2005; 77: 2297.
  • 8
    Hand O. W., Majumdar T. K., Cooks R. G., Effects of Primary Ion Polyatomicity and Kinetic-Energy on Secondary Ion Yield and Internal Energy in Sims. International Journal of Mass Spectrometry and Ion Processes 1990; 97: 35.
  • 9
    Diehnelt C. W., Van Stipdonk M. J., Schweikert E. A., Effectiveness of atomic and polyatomic primary ions for organic secondary ion mass spectrometry. International Journal of Mass Spectrometry 2001; 207: 111.
  • 10
    Harris R. D., Van Stipdonk M. J., Schweikert E. A., Kiloelectron volt cluster impacts: prospects for cluster-SIMS. International Journal of Mass Spectrometry 1998; 174: 167.
  • 11
    Mahoney J. F., Parilis E. S., Lee T. D., Large Biomolecule Desorption by Massive Cluster-Impact. Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms 1994; 88: 154.
  • 12
    Cornett D. S., Lee T. D., Mahoney J. F., Matrix-Free Desorption of Biomolecules Using Massive Cluster-Impact. Rapid Communications in Mass Spectrometry 1994; 8: 996.
  • 13
    Sigmund P., Bitensky I. S., Jensen J., Molecule and cluster bombardment: Energy loss, trajectories, and collision cascades. Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms 1996; 112: 1.
  • 14
    Cooks R. G., Jo S. C., Green J., Collisions of organic ions at surfaces. Applied Surface Science 2004; 231-2: 13.
  • 15
    Gologan B., Green J. R., Alvarez J., Laskin J., Cooks R. G., Ion/surface reactions and ion soft-landing. Physical Chemistry Chemical Physics 2005; 7: 1490.
  • 16
    Kasi S. R., Kang H., Sass C. S., Rabalais J. W., Inelastic Processes in Low-Energy Ion-Surface Collisions. Surface Science Reports 1989; 10: 1.
  • 17
    Mahoney J. F., Perel J., Ruatta S. A., Martino P. A., Husain S., Lee T. D., Massive Cluster Impact Mass-Spectrometry—a New Desorption Method for the Analysis of Large Biomolecules. Rapid Communications in Mass Spectrometry 1991; 5: 441.
  • 18
    Mahoney J. F., Cornett D. S., Lee T. D., Formation of Multiply-Charged Ions from Large Molecules Using Massive-Cluster Impact. Rapid Communications in Mass Spectrometry 1994; 8: 403.
  • 19
    Takats Z., Cotte-Rodriguez I., Talaty N., Chen H. W., Cooks R. G., Direct, trace level detection of explosives on ambient surfaces by desorption electrospray ionization mass spectrometry. Chemical Communications 2005; 15: 1950.
  • 20
    Riter L. S., Peng Y. A., Noll R. J., Patterson G. E., Aggerholm T., Cooks R. G., Analytical performance of a miniature cylindrical ion trap mass spectrometer. Analytical Chemistry 2002; 74: 6154.
  • 21
    Lin B. W., Sunner J., Ion-Transport by Viscous-Gas Flow-through Capillaries. Journal of the American Society for Mass Spectrometry 1994; 5: 873.
  • 22
    Takats Z., Wiseman J. M., Gologan B., Cooks R. G., Electrosonic spray ionization. A gentle technique for generating folded proteins and protein complexes in the gas phase and for studying ion—Molecule reactions at atmospheric pressure. Analytical Chemistry 2004; 76: 4050.
  • 23
    Wiseman J. M., Puolitaival S. M., Takats Z., Caprioli R. M., Cooks R. G., Mass Spectrometric Profiling of Biological Tissues by using Desorption Electrospray Ionization. Angewandte Chemie-International Edition 2005; In press.
  • 24
    Myung S., Wiseman J. M., Valentine S. J., Takats Z., Cooks R. G., Clemmer D. E., Coupling Desorption Electrospray Ionization (DESI) with Ion Mobility/Mass Spectrometry for Analysis of Protein Structure: Evidence for Emission of Folded and Denatured States. Journal of Physical Chemistry A 2005; Submitted.
  • 25
    Liu H. Y., Montaser A., Phase-Doppler Diagnostic Studies of Primary and Tertiary Aerosols Produced by a High-Efficiency Nebulizer. Analytical Chemistry 1994; 66: 3233.
  • 26
    Gomez A., Tang K. Q., Charge and Fission of Droplets in Electrostatic Sprays. Physics of Fluids 1994; 6: 404.
  • 27
    Takats Z., Nanita S. C., Cooks R. G., Schlosser G., Vekey K., Amino acid clusters formed by sonic spray ionization. Analytical Chemistry 2003; 75: 1514.
  • 28
    Haller K. K., Poulikakos D., Ventikos Y., Monkewitz P., Shock wave formation in droplet impact on a rigid surface: lateral liquid motion and multiple wave structure in the contact line region. Journal of Fluid Mechanics 2003; 490: 1.
  • 29
    Chen H., Talaty N., Takats Z., Cooks R. G., Desorption Electrospray Ionization Mass Spectrometry for High Throughput Analysis of Pharmaceutical Samples in the Ambient Environment. Analytical Chemistry 2005; In press.
  • 30
    Tao W. A., Zhang D. X., Wang F., Thomas P. D., Cooks R. G., Kinetic resolution of D,L-amino acids based on gas-phase dissociation of copper(II) complexes. Analytical Chemistry 1999; 71: 4427.
  • 31
    Tao W. A., Zhang D. X., Nikolaev E. N., Cooks R. G., Copper(II)-assisted enantiomeric analysis of D,L-amino acids using the kinetic method: Chiral recognition and quantification in the gas phase. Journal of the American Chemical Society 2000; 122: 10598.
  • 32
    Cooks R. G., Patrick J. S., Kotiaho T., McLuckey S. A., Thermochemical Determinations by the Kinetic Method. Mass Spectrometry Reviews 1994; 13: 287.
  • 33
    Talaty N., Takats Z., Cooks R. G., Desorption Electrospray Ionization (DESI) of Natural Products: Alkaloid Detection by Mass Spectrometry in Plant Tissue under Ambient Conditions. Analyst 2005; Submitted.
  • 34
    Chen H., Zhengzheng P., Talaty N., Cooks R. G., Raftery M. D., Combining Desorption Electrospray Ionization Mass Spectrometry and Nuclear Magnetic Resonance for Differential Metabolomics without Sample Preparation. Chemical Communications 2005; Submitted.
  • 35
    Fenselau C., Demirev P. A., Characterization of intact microorganisms by MALDI mass spectrometry. Mass Spectrometry Reviews 2001; 20: 157.
  • 36
    Meuzelaa Hl, Kistemak Pg, Technique for Fast and Reproducible Fingerprinting of Bacteria by Pyrolysis Mass-Spectrometry. Analytical Chemistry 1973; 45: 587.
  • 37
    Cargile B. J., McLuckey S. A., Stephenson J. L., Identification of bacteriophage MS2 coat protein from E-coli lysates via ion trap collisional activation of intact protein ions. Analytical Chemistry 2001; 73: 1277.
  • 38
    Todd P. J., Schaaff T. G., Chaurand P., Caprioli R. M., Organic ion imaging of biological tissue with secondary ion mass spectrometry and matrix-assisted laser desorption/ionization. Journal of Mass Spectrometry 2001; 36: 355.
  • 39
    Altelaar A. F. M., van Minnen J., Jimenez C. R., Heeren R. M. A., Piersma S. R., Direct molecular Imaging of Lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry. Analytical Chemistry 2005; 77: 735.
  • 40
    Caprioli R. M., Farmer T. B., Gile J., Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS. Analytical Chemistry 1997; 69: 4751.
  • 41
    McDonnell L. A., Piersma S. R., Altelaar A. F. M., Mize T. H., Luxembourg S. L., Verhaert P., van Minnen J., Heeren R. M. A., Subcellular imaging mass spectrometry of brain tissue. Journal of Mass Spectrometry 2005; 40: 160.
  • 42
    Ostrowski S. G., Van Bell C. T., Winograd N., Ewing A. G., Mass spectrometric imaging of highly curved membranes during Tetrahymena mating. Science 2004; 305: 71.
  • 43
    Sjovall P., Lausmaa J., Johansson B., Mass spectrometric imaging of lipids in brain tissue. Analytical Chemistry 2004; 76: 4271.
  • 44
    Stoeckli M., Chaurand P., Hallahan D. E., Caprioli R. M., Imaging mass spectrometry: A new technology for the analysis of protein expression in mammalian tissues. Nature Medicine 2001; 7: 493.
  • 45
    Touboul D., Halgand F., Brunelle A., Kersting R., Tallarek E., Hagenhoff B., Laprevote O., Tissue molecular ion imaging by gold cluster ion bombardment. Analytical Chemistry 2004; 76: 1550.