  1. 1
    Jin Wook Kim, Jae Ha Hwang, In Kyeong Kim, Young Eun Kim, Hui-Jun Yang, Gwanhee Ehm, Han-Joon Kim, Dong Gyu Kim, Sun Ha Paek, Beom S. Jeon, Acute brain reaction to DBS electrodes after deep brain stimulation: chronological observation, Acta Neurochirurgica, 2013, 155, 12, 2365

    CrossRef

  2. 2
    Karl A. Sillay, Paul Rutecki, Kathy Cicora, Greg Worrell, Joseph Drazkowski, Jerry J. Shih, Ashwini D. Sharan, Martha J. Morrell, Justin Williams, Brett Wingeier, Long-Term Measurement of Impedance in Chronically Implanted Depth and Subdural Electrodes During Responsive Neurostimulation in Humans, Brain Stimulation, 2013, 6, 5, 718

    CrossRef

  3. 3
    José Fidel Baizabal Carvallo, Giovanni Mostile, Mike Almaguer, Anthony Davidson, Richard Simpson, Joseph Jankovic, Deep Brain Stimulation Hardware Complications in Patients with Movement Disorders: Risk Factors and Clinical Correlations, Stereotactic and Functional Neurosurgery, 2012, 90, 5, 300

    CrossRef

  4. 4
    Jorge Guridi, Maria C. Rodriguez-Oroz, Manuel Alegre, Jose A. Obeso, Hardware complications in deep brain stimulation: Electrode impedance and loss of clinical benefit, Parkinsonism & Related Disorders, 2012, 18, 6, 765

    CrossRef

  5. 5
    Kazuhiro Samura, Yasushi Miyagi, Tsuyoshi Okamoto, Takehito Hayami, Junji Kishimoto, Mitsuo Katano, Kazufumi Kamikaseda, Short circuit in deep brain stimulation, Journal of Neurosurgery, 2012, 117, 5, 955

    CrossRef

  6. 6
    Sierra Farris, Monique Giroux, Deep brain stimulation: A review of the procedure and the complications, Journal of the American Academy of Physician Assistants, 2011, 24, 2, 39

    CrossRef

  7. 7
    José Fidel Baizabal Carvallo, Richard Simpson, Joseph Jankovic, Diagnosis and treatment of complications related to deep brain stimulation hardware, Movement Disorders, 2011, 26, 8
  8. 8
    Arnar Astradsson, Patrick M. Schweder, Carole Joint, Alexander L. Green, Tipu Z. Aziz, Twiddler’s syndrome in a patient with a deep brain stimulation device for generalized dystonia, Journal of Clinical Neuroscience, 2011, 18, 7, 970

    CrossRef

  9. 9
    Stanley Fahn, Joseph Jankovic, Mark Hallett, Principles and Practice of Movement Disorders, 2011,

    CrossRef

  10. 10
    Fernando Seijo Fernández, Marco Antonio Alvarez Vega, Aida Antuña Ramos, Fernando Fernández González, Beatriz Lozano Aragoneses, Lead Fractures in Deep Brain Stimulation during Long-Term Follow-Up, Parkinson's Disease, 2010, 2010, 1

    CrossRef

  11. 11
    Sierra Farris, Monique Lillian Giroux, Lead Wire Fracture Associated With Normal Therapeutic Impedance Measurements in a Patient With a Kinetra Neurostimulator, Neuromodulation: Technology at the Neural Interface, 2010, 13, 1
  12. 12
    Karl A. Sillay, Jason C. Chen, Erwin B. Montgomery, Long-Term Measurement of Therapeutic Electrode Impedance in Deep Brain Stimulation, Neuromodulation: Technology at the Neural Interface, 2010, 13, 3
  13. 13
    Hu Liang Low, Reply: The ‘plait sign’ of neurostimulator torsion, Movement Disorders, 2010, 25, 7
  14. 14
    Tobias Wächter, Daniel Weiss, Sorin Breit, Thomas Gasser, Rejko Krüger, Alireza Gharabaghi, Severe muscular fasciculations as an uncommon side-effect due to microdefect of an extension wire in deep brain stimulation, Movement Disorders, 2009, 24, 14