SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Dixon WT. Simple proton spectroscopic imaging. Radiology 1984; 153: 189194.
  • 2
    Paltiel Z. Separate water and lipids images obtained by a single scan. In: Proceedings of the 4th Annual Meeting of SMRM, New York, NY, USA, 1985. p 172173.
  • 3
    Patrick JL, Haacke EM, Hahn JE. Water/fat separation and chemical shift artifact correction using a single scan. In: Proceedings of the 4th Annual Meeting of SMRM, New York, NY, USA, 1985. p 174175.
  • 4
    Ahn CB, Lee SY, Nalcioglu O, Cho ZH. Spectroscopic imaging by quadrature modulated echo time shifting. Magn Reson Imaging 1986; 4: 110111.
  • 5
    Rosen BR, Fleming DM, Kushner DC, Zaner KS, Buxton RB, Bennet WP, Wismer GL, Brady TJ. Hemotologic bone marrow disorders: quantitative chemical shift MR imaging. Radiology 1988; 169: 799804.
  • 6
    Wang Y, Li D, Haacke EM, Brown JJ. A three-point Dixon method for water and fat separation using 2D and 3D gradient-echo techniques. J Magn Reson Imaging 1998; 8: 703710.
  • 7
    Yeung HN, Kormos DW. Separation of true fat and water images by correcting magnetic field inhomogeneity in situ. Radiology 1986; 159: 783786.
  • 8
    Lodes CC, Felmlee JP, Ehman RL, Sehgal CM, Greenleaf JF, Glover GH, Gray JE. Proton MR chemical shift imaging using double and triple phase contrast acquisition methods. J Comput Assist Tomogr 1989; 13: 855861.
  • 9
    Glover GH, Schneider E. Three-point Dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magn Reson Med 1991; 18: 371383.
  • 10
    Glover GH. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991; 1: 521530.
  • 11
    Hardy PA, Hinks RS, Tkach JA. Separation fat and water in fast-spin-echo MR imaging with the three-point Dixon technique. J Magn Reson Imaging 1995; 5: 181185.
  • 12
    Bernstein MA, King KF, Zhou XJ. Handbook of MRI pulse sequences. New York: Elsevier Academic Press; 2004.
  • 13
    Xiang QS, An L, Aikins D, MacKay A. Phase correction in two-point Dixon chemical shift imaging. In: Proceedings of the 3rd Annual Meeting of SMR, Nice, France, 1995. p 1904.
  • 14
    Coombs BD, Szumowski J, Coshow W, Li F. Two-point Dixon technique for water-fat signal decomposition with B0 inhomogeneity correction. In: Proceedings of the 3rd Annual Meeting of SMR, Nice, France, 1995. p 647.
  • 15
    Akkerman EM, Maas M. A region-growing algorithm to simultaneously remove dephasing influences and separate fat and water in two-point Dixon imaging. In: Proceedings of the 3rd Annual Meeting of SMR, Nice, France, 1995. p 649.
  • 16
    Skinner TE, Glover GH. An extended two-point Dixon algorithm for calculating separate water, fat, and B0 images. Magn Reson Med 1997; 37: 628630.
  • 17
    Xiang QS, An L. Water-fat imaging with direct phase encoding. J Magn Reson Imaging 1997; 7: 10021015.
  • 18
    Judge TR, Bryanston-Cross PJ. A review of phase unwrapping techniques in fringe analysis. Optics Lasers Eng 1994; 21: 199239.
  • 19
    Ghiglia DC, Pritt MD. Two-dimensional phase unwrapping: theory, algorithms, and software. 1st ed. New York: Wiley; 1998.
  • 20
    Chavez S, Xiang QS, An L. Understanding phase in MRI: a new cutline phase unwrapping method. IEEE Trans Med Imaging 2002; 21: 966977.
  • 21
    Sargent M, Poskitt KJ, Xiang QS. An L. Application of a three-point method for water-fat MR imaging in children. Pediatr Radiol 1999; 29: 444448.
  • 22
    Carson B, Xiang QS. Fat suppression using direct phase encoding: musculoskeletal applications using MR imaging. AJR Am J Roentgenol 1999; 173: 230233.
  • 23
    An L, Xiang QS. Water-fat imaging with three orthogonal-phase acquisitions. In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia, 1998. p 1866.
  • 24
    Ma J, Singh SK, Kumar AJ, Leeds NE, Broemeling LD. Phased array coil compatible T2-weighted fast spin echo Dixon imaging. In: Proceedings of the 10th Annual Meeting of ISMRM, Honolulu, HI, USA, 2002. p 735.
  • 25
    Ma J, Bankson JA, Stafford RJ. Multipoint Dixon imaging using sensitivity encoding. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003. p 1069.
  • 26
    An L, Xiang QS. Chemical shift imaging with spectrum modeling. Magn Reson Med 2001; 46: 126130.
  • 27
    Reeder SB, Wen Z, Yu H, Pineda AR, Gold GE, Markl M, Pelc NJ. Multicoil Dixon chemical species separation with an iterative least-squares estimation method. Magn Reson Med 2004; 51: 3545.
  • 28
    Yu H, Reeder SB, Shimakawa A, Brittain JH, Pelc NJ. Field map estimation with a region growing scheme for iterative three-point water-fat decomposition. Magn Reson Med 2005; 54: 10321039.
  • 29
    Ma J. Breath-hold water and fat imaging using a dual-echo two-point technique with an efficient and robust phase-correction algorithm. Magn Reson Med 2004; 52: 415419.
  • 30
    Ma J, Vu AT, Son JB, Coi H, Hazle J. Fat-suppressed three-dimensional dual echo Dixon technique for contrast agent enhanced MRI. J Magn Reson Imaging 2006; 23: 3641.
  • 31
    An L, Xiang QS. Quadrature two-point water-fat imaging. In: Proceedings of the 4th Annual Meeting of ISMRM, New York, NY, USA, 1996. p 1541.
  • 32
    An L. Water-fat imaging and general chemical shift imaging with spectrum modeling. Ph.D. dissertation, University of British Columbia, Vancouver, Canada, 1998.
  • 33
    Xiang QS. Water-fat imaging with partially-opposed-phase (POP) acquisition: an asymmetric Dixon method. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003. p 1130.
  • 34
    Wolfram S. A new kind of science. Champaign, IL: Wolfram Media; 2002.
  • 35
    Cipra BA. An introduction to the Ising model. Am Math Monthly 1987; 94: 937959.
  • 36
    Ghiglia DC, Mastin GA, Romero LA. Cellular-automata method for phase unwrapping. J Opt Soc Am 1987; 4A: 267280.
  • 37
    Henkelman RM. Measurement of signal intensities in the presence of noise in MR images. Med Phys 1985; 12: 232233.
  • 38
    Xiang QS. IR image reconstruction with multi-seed region growing spin reversal (RGSR). J Magn Reson Imaging 1996; 6: 775782.
  • 39
    Mazumdar A, Hargreaves B, Han E, Brau A, Yu H, Brittain J. Automated fat-water identification in phase sensitive SSFP. In: Proceedings of the 13th Annual Meeting of ISMRM, Miami Beach, FL, USA, 2005. p 2307.
  • 40
    Wen Z, Reeder SB, Pineda AR, Glover GH, Pelc NJ. Noise performance study of symmetric three point Dixon method. In: Proceedings of the 11th Annual Meeting of ISMRM, Toronto, Canada, 2003. p 483.