Get access

Maximum efficiency radiofrequency shimming: Theory and initial application for hip imaging at 7 tesla

Authors

  • Cem Murat Deniz,

    Corresponding author
    1. Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
    2. Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
    • Bernard and Irene Schwartz Center for Biomedical Imaging, New York University School of Medicine, 660 First Avenue, Room 420, New York, NY 10016
    Search for more papers by this author
  • Ryan Brown,

    1. Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
    Search for more papers by this author
  • Riccardo Lattanzi,

    1. Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
    2. Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
    Search for more papers by this author
  • Leeor Alon,

    1. Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
    2. Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
    Search for more papers by this author
  • Daniel K. Sodickson,

    1. Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
    2. Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
    Search for more papers by this author
  • Yudong Zhu

    1. Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
    2. Sackler Institute of Graduate Biomedical Sciences, New York University School of Medicine, New York, New York, USA
    Search for more papers by this author

Abstract

Radiofrequency shimming with multiple channel excitation has been proposed to increase the transverse magnetic field uniformity and reduce specific absorption rate at high magnetic field strengths (≥7 T) where high-frequency effects can make traditional single channel volume coils unsuitable for transmission. In the case of deep anatomic regions and power-demanding pulse sequences, optimization of transmit efficiency may be a more critical requirement than homogeneity per se. This work introduces a novel method to maximize transmit efficiency using multiple channel excitation and radiofrequency shimming. Shimming weights are calculated in order to obtain the lowest possible net radiofrequency power deposition into the subject for a given transverse magnetic field strength. The method was demonstrated in imaging studies of articular cartilage of the hip joint at 7 T. We show that the new radiofrequency shimming method can enable reduction in power deposition while maintaining an average flip angle or adiabatic condition in the hip cartilage. Building upon the improved shimming, we further show that the signal-to-noise ratio in hip cartilage at 7 T can be substantially greater than that at 3 T, illustrating the potential benefits of high field hip imaging. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.