Get access

Comprehensive inter-laboratory calibration of reference materials for δ18O versus VSMOW using various on-line high-temperature conversion techniques

Authors

  • Willi A. Brand,

    Corresponding author
    1. MPI-BGC, Max-Planck-Institute for Biogeochemistry, Beutenberg Campus, P.O. Box 100164, 07701 Jena, Germany
    • MPI-BGC, Max-Planck-Institute for Biogeochemistry, Beutenberg Campus, P.O. Box 100164, 07701 Jena, Germany.
    Search for more papers by this author
  • Tyler B. Coplen,

    Corresponding author
    1. USGS, U.S. Geological Survey, 431 National Center, Reston, VA 20192, USA
    • USGS, U.S. Geological Survey, 431 National Center, Reston, VA 20192, USA.
    Search for more papers by this author
    • The contributions of T. B. Coplen , J. K. Böhlke and S. J. Mroczkowski to this article were prepared as part of their official duties as United States Federal Government employees.

  • Anita T. Aerts-Bijma,

    1. CIO, Centre for Isotope Research, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands
    Search for more papers by this author
  • J. K. Böhlke,

    1. USGS, U.S. Geological Survey, 431 National Center, Reston, VA 20192, USA
    Search for more papers by this author
    • The contributions of T. B. Coplen , J. K. Böhlke and S. J. Mroczkowski to this article were prepared as part of their official duties as United States Federal Government employees.

  • Matthias Gehre,

    1. UFZ, Helmholtz-Centre for Environmental Research, Laboratory for Stable Isotopes, Permoserstrasse 15, 04318 Leipzig, Germany
    Search for more papers by this author
  • Heike Geilmann,

    1. MPI-BGC, Max-Planck-Institute for Biogeochemistry, Beutenberg Campus, P.O. Box 100164, 07701 Jena, Germany
    Search for more papers by this author
  • Manfred Gröning,

    1. IAEA, International Atomic Energy Agency, Isotope Hydrology Laboratory, P.O. Box 100, A-1400 Vienna, Austria
    Search for more papers by this author
  • Henk G. Jansen,

    1. CIO, Centre for Isotope Research, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands
    Search for more papers by this author
  • Harro A. J. Meijer,

    1. CIO, Centre for Isotope Research, University of Groningen, Nijenborgh 4, 9747 AG Groningen, The Netherlands
    Search for more papers by this author
  • Stanley J. Mroczkowski,

    1. USGS, U.S. Geological Survey, 431 National Center, Reston, VA 20192, USA
    Search for more papers by this author
    • The contributions of T. B. Coplen , J. K. Böhlke and S. J. Mroczkowski to this article were prepared as part of their official duties as United States Federal Government employees.

  • Haiping Qi,

    1. USGS, U.S. Geological Survey, 431 National Center, Reston, VA 20192, USA
    Search for more papers by this author
  • Karin Soergel,

    1. ETH Zurich, Institute of Plant Sciences, Universitätsstrasse 2, CH-8092 Zurich, Switzerland
    Current affiliation:
    1. Leibniz Institute for Zoo and Wildlife Research (IWZ), Alfred-Kowalke-Strasse 17, 10315 Berlin, Germany.
    Search for more papers by this author
  • Hilary Stuart-Williams,

    1. ANU, The Australian National University, Research School of Biological Sciences, Canberra, ACT 0200 Australia
    Search for more papers by this author
  • Stephan M. Weise,

    1. UFZ, Helmholtz-Centre for Environmental Research, Laboratory for Stable Isotopes, Theodor-Lieser-Strasse 4, 06120 Halle, Germany
    Search for more papers by this author
  • Roland A. Werner

    1. ETH Zurich, Institute of Plant Sciences, Universitätsstrasse 2, CH-8092 Zurich, Switzerland
    Search for more papers by this author

Abstract

Internationally distributed organic and inorganic oxygen isotopic reference materials have been calibrated by six laboratories carrying out more than 5300 measurements using a variety of high-temperature conversion techniques (HTC)a in an evaluation sponsored by the International Union of Pure and Applied Chemistry (IUPAC). To aid in the calibration of these reference materials, which span more than 125‰, an artificially enriched reference water (δ18O of +78.91‰) and two barium sulfates (one depleted and one enriched in 18O) were prepared and calibrated relative to VSMOW2b and SLAP reference waters. These materials were used to calibrate the other isotopic reference materials in this study, which yielded:

Reference materialδ18O and estimated combined uncertainty c
IAEA-602 benzoic acid+71.28 ± 0.36‰
USGS35 sodium nitrate+56.81 ± 0.31‰
IAEA-NO-3 potassium nitrate+25.32 ± 0.29‰
IAEA-601 benzoic acid+23.14 ± 0.19‰
IAEA-SO-5 barium sulfate+12.13 ± 0.33‰
NBS 127 barium sulfate+8.59 ± 0.26‰
VSMOW2 water0‰
IAEA-600 caffeine−3.48 ± 0.53‰
IAEA-SO-6 barium sulfate−11.35 ± 0.31‰
USGS34 potassium nitrate−27.78 ± 0.37‰
SLAP water−55.5‰

The seemingly large estimated combined uncertainties arise from differences in instrumentation and methodology and difficulty in accounting for all measurement bias. They are composed of the 3-fold standard errors directly calculated from the measurements and provision for systematic errors discussed in this paper. A primary conclusion of this study is that nitrate samples analyzed for δ18O should be analyzed with internationally distributed isotopic nitrates, and likewise for sulfates and organics. Authors reporting relative differences of oxygen-isotope ratios (δ18O) of nitrates, sulfates, or organic material should explicitly state in their reports the δ18O values of two or more internationally distributed nitrates (USGS34, IAEA-NO-3, and USGS35), sulfates (IAEA-SO-5, IAEA-SO-6, and NBS 127), or organic material (IAEA-601 benzoic acid, IAEA-602 benzoic acid, and IAEA-600 caffeine), as appropriate to the material being analyzed, had these reference materials been analyzed with unknowns. This procedure ensures that readers will be able to normalize the δ18O values at a later time should it become necessary.

The high-temperature reduction technique for analyzing δ18O and δ2H is not as widely applicable as the well-established combustion technique for carbon and nitrogen stable isotope determination. To obtain the most reliable stable isotope data, materials should be treated in an identical fashion; within the same sequence of analyses, samples should be compared with working reference materials that are as similar in nature and in isotopic composition as feasible. Copyright © 2009 John Wiley & Sons, Ltd.