SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    L. S. Eberlin, C. R. Ferreira, A. L. Dill, D. R. Ifa, R. G. Cooks. Desorption electrospray ionization mass spectrometry for lipid characterization and biological tissue imaging. Biochim. Biophys. Acta 2011, 1811, 946.
  • 2
    J. M. Wiseman, D. R. Ifa, Q. Song, R. G. Cooks. Tissue imaging at atmospheric pressure using desorption electrospray ionization (DESI) mass spectrometry. Angew. Chem. Int. Ed. 2006, 45, 7188.
  • 3
    Z. Takáts, J. M. Wiseman, B. Gologan, R. G. Cooks. Mass spectrometry sampling under ambient conditions with desorption electrospray ionization. Science 2004, 306, 471.
  • 4
    A. B. Costa, R. G. Cooks. Simulated splashes: Elucidating the mechanism of desorption electrospray ionization mass spectrometry. Chem. Phys. Lett. 2008, 464, 1.
  • 5
    A. Venter, P. E. Sojka, R. G. Cooks. Droplet dynamics and ionization mechanisms in desorption electrospray ionization mass spectrometry. Anal. Chem. 2006, 78, 8549.
  • 6
    M. Girod, Y. Shi, J.-X. Cheng, R. G. Cooks. Desorption electrospray ionization imaging mass spectrometry of lipids in rat spinal cord. J. Am. Soc. Mass Spectrom. 2010, 21, 1177.
  • 7
    K. A. Douglass, S. Jain, W. R. Brandt, A. R. Venter. Deconstructing desorption electrospray ionization: Independent optimization of desorption and ionization by spray desorption collection. J. Am. Soc. Mass Spectrom. 2012, 23, 1896.
  • 8
    M. H. Ross, G. I. Kaye, P. Wojciech. Histology – A Text and Atlas, (4th edn.). Lippincott Williams & Wilkins, 2006, pp. 532541.
  • 9
    J. S. Page, B. Bogdanov, A. N. Vilkov, D. C. Prior, M. A. Buschbach, K. Tang, R. D. Smith. Automatic gain control in mass spectrometry using a jet disrupter electrode in an electrodynamic ion funnel. J. Am. Soc. Mass Spectrom. 2005, 16, 244.
  • 10
    M. V. Gorshkov, D. M. Good, Y. Lyutvinskiy, H. Yang, R. A. Zubarev. Calibration function for the Orbitrap FTMS accounting for the space charge effect. J. Am. Soc. Mass Spectrom. 2010, 21, 1846.
  • 11
    J. V. Olsen, J. C. Schwartz, J. Griep-Raming, M. L. Nielsen, E. Damoc, E. Denisov, O. Lange, P. Remes, D. Taylor, M. Splendore, E. R. Wouters, M. Senko, A. Makarov, M. Mann, S. Horning. A dual pressure linear ion trap Orbitrap instrument with very high sequencing speed. Mol. Cell. Proteomics 2009, 8, 2759.
  • 12
    D. K. Williams, D. C. Muddiman. Parts-per-billion mass measurement accuracy achieved through the combination of multiple linear regression and automatic gain control in a Fourier transform ion cyclotron resonance mass spectrometer. Anal. Chem. 2007, 79, 5058.