• Open Access

Wear and metallographic analysis of WaveOne and reciproc NiTi instruments before and after three uses in root canals

Authors

  • Chiara Pirani,

    Corresponding author
    1. Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences (DIBINEM), School of Dentistry, University of Bologna—Alma Mater Studiorum, Bologna, Italy
    • Address for reprints: C. Pirani, Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences (DIBINEM), School of Dentistry, University of Bologna—Alma Mater Studiorum, Bologna, Italy

      E-mail: chiara.pirani4@unibo.it

    Search for more papers by this author
  • Alessandro Paolucci,

    1. Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences (DIBINEM), School of Dentistry, University of Bologna—Alma Mater Studiorum, Bologna, Italy
    Search for more papers by this author
  • Oddone Ruggeri,

    1. Department of Mechanical Engineering, University of Bologna—Alma Mater Studiorum, Bologna, Italy
    Search for more papers by this author
  • Maurizio Bossù,

    1. Department of Oral and Maxillo Facial Sciences, Sapienza University of Rome, Rome, Italy
    Search for more papers by this author
  • Antonella Polimeni,

    1. Department of Oral and Maxillo Facial Sciences, Sapienza University of Rome, Rome, Italy
    Search for more papers by this author
  • Maria Rosaria Antonella Gatto,

    1. Division of Orthodontics and Gnatology, Department of Biomedical and Neuromotor Sciences (DIBINEM), School of Dentistry, University of Bologna—Alma Mater Studiorum, Bologna, Italy
    Search for more papers by this author
  • Maria Giovanna Gandolfi,

    1. Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences (DIBINEM), School of Dentistry, University of Bologna—Alma Mater Studiorum, Bologna, Italy
    Search for more papers by this author
  • Carlo Prati

    1. Endodontic Clinical Section, Department of Biomedical and Neuromotor Sciences (DIBINEM), School of Dentistry, University of Bologna—Alma Mater Studiorum, Bologna, Italy
    Search for more papers by this author

  • Conflicts of interest: None.

Summary

Reciprocating instruments made from M-wire alloy have been proposed to reduce the risk of fracture. No information is available on the surface alteration after single and multiple uses in root canals. Two reciprocating NiTi instruments were used on extracted teeth up to three times. ESEM/EDS analysis was conducted to determine defects, alterations, and wear features of the apical third of instruments and metallographic analysis was performed on the cross-section of new and used instruments to compare alloy properties. Topography of apical portion was evaluated by AFM before and after uses. Extracted single-rooted teeth were divided into two groups and instrumented according to the manufacturer's recommendations with: (A) WaveOne Primary and (B) Reciproc R25. Each group was divided into three subgroups according to the number of canals instrumented: 1, 2, and 3, respectively. Chi square test was performed to verify homogeneity of defects distribution and GLM to evaluate the differences of RMS at baseline and after use for both groups (α level 0.05). No instrument fractured and no spiral distortions were observed under optical microscope even when the number of uses increased. Not significant differences were found for WaveOne and Reciproc. Blades presented a wrapped portion in WaveOne group and a more symmetrical feature in Reciproc group. Metallographic analysis revealed in both groups the presence of twinned martensitic grains with isolated flat austenitic areas. Both instruments demonstrated limited alteration, such as tip deformation and wear. This study confirmed the safe clinical use of both instruments for shaping multi-rooted teeth. SCANNING 36:517–525, 2014. © 2014 Wiley Periodicals, Inc.