Original Paper
Accuracy of ultrasound subjective ‘pattern recognition’ for the diagnosis of borderline ovarian tumors
Article first published online: 20 APR 2007
DOI: 10.1002/uog.4002
Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.
Additional Information
How to Cite
Yazbek, J., Raju, K. S., Ben-Nagi, J., Holland, T., Hillaby, K. and Jurkovic, D. (2007), Accuracy of ultrasound subjective ‘pattern recognition’ for the diagnosis of borderline ovarian tumors. Ultrasound in Obstetrics & Gynecology, 29: 489–495. doi: 10.1002/uog.4002
Publication History
- Issue published online: 20 APR 2007
- Article first published online: 20 APR 2007
- Manuscript Accepted: 25 JAN 2007
- Abstract
- Article
- References
- Cited By
Keywords:
- benign;
- borderline;
- malignant;
- ovarian tumors;
- ultrasound
Abstract
Objectives
To assess the value of pattern recognition for the preoperative ultrasound diagnosis of borderline ovarian tumors (BOTs).
Methods
This was a prospective study of women who were referred to our regional cancer center with the diagnosis of an adnexal mass on a Level II (routine) gynecological ultrasound scan. Women with lesions of uncertain nature were referred for a Level III (expert) ultrasound scan in our tertiary center. The tumor pattern recognition method was used to differentiate between various types of ovarian tumors. Morphological features suggestive of BOTs were: unilocular cyst with a positive ovarian crescent sign and extensive papillary projections arising from the inner wall, or a cyst with a well defined multilocular nodule. The ultrasound findings were compared with the final histological diagnosis.
Results
A total of 224 women with an adnexal mass of uncertain nature were referred for an expert scan, 166 (74.1%) of whom underwent surgery. In this group of women the final histological diagnoses were: 99 (60%) benign lesions, 32 (19%) invasive ovarian cancer and 35 (21%) BOTs. Using pattern recognition combining the different morphological features, a correct preoperative diagnosis of BOT was made in 24/35 (68.6%) women: area under the receiver–operating characteristics curve 0.812 (standard error 0.049; 95% CI, 0.716–0.908), sensitivity 0.69 (95% CI, 0.52–0.81), specificity 0.94 (95% CI, 0.88–0.97), positive likelihood ratio 11.3 (95% CI, 5.53–22.8) and negative likelihood ratio 0.34 (95% CI, 0.21–0.55).
Conclusions
Ultrasound diagnosis of BOTs is highly specific. However, typical features are absent in one-third of cases, which are typically misdiagnosed as benign lesions. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.

1469-0705/asset/olbannerleft.gif?v=1&s=59e39ba3610da7ddc083043265583df1fc636f8e)
1469-0705/asset/olbannerright.gif?v=1&s=325d39d901af70d06023c952adb9197e6d34d8fe)
