SEARCH

SEARCH BY CITATION

References

  • 1
    Ager, S., Scott, M.A., Mahendra, P., Richards, E.M., Jestice, H.K., Beraks, P., Baglin, T.P., Marcus, R.E. (1995) Peripheral blood stem cell transplants after high-dose therapy in patients with malignant lymphoma: a retrospective comparison with autologous bone marrow transplantation. Bone Marrow Transplantation, 16, 79 83.
  • 2
    Andrews, R.G., Bryant, E.M., Bartelmez, S.H., Muirhead, D.Y., Knitter, G.H., Bensinger, W., Strong, D.M., Bernstein, I.D. (1992) CD34+marrow cells, devoid of T and B lymphocytes, reconstitute stable lymphopoiesis and myelopoiesis in lethally irradiated baboons . Blood, 80, 1693 1701.
  • 3
    Appelbaum, F.R. (1979) Hemopoietic reconstitution following autologous bone marrow and peripheral blood mononuclear cell infusions. Experimental Hematology, 8, 7 11.
  • 4
    Barnett, D., Granger, V., Mayr, P., Fay, S.P., Reilly, J.T. (1995) Preparation and stabilization of cells. WO 95/01796 (International Publication Number), pp. 1–31.
  • 5
    Barnett, D., Granger, V., Mayr, P., Storie, I., Wilson, G.A., Reilly, J.T. (1996) Evaluation of a novel stable whole blood quality control material for lymphocyte subset analysis: results from the UK NEQAS Immune Monitoring Scheme. Cytometry, 26, 216 222.
  • 6
    Barnett, D., Granger, V., Reilly, J.T. (1994) The United Kingdom External Quality Assurance Schemes (UK NEQAS) for leukaemia phenotyping. British Journal of Haematology, 86, (Suppl. 1), 83.
  • 7
    Bender, J., To, L.B., Williams, S., Schwartzberg, L. (1992) Defining a therapeutic dose of peripheral blood stem cells. Journal of Hematotherapy, 1, 329 342.
  • 8
    Bender, J.G., Unverzagt, K., Walker, D. (1994) Guidelines for determination of CD34+ cells by flow cytometry: application to the harvesting and transplantation of peripheral blood stem cells. Hematopoietic Stem Cells: The Mulhouse Manual (ed. by E. Wunder, H. Sovalat, P. Henon and S. Serke), p. 31. AlphaMed Press, Dayton.
  • 9
    Berenson, R.J., Andrews, R.G., Bensinger, W.J., Kalamasz, D., Knitter, G., Buckner, C.D., Bernstein, I.D. (1988) Antigen CD34-positive marrow cells engraft lethally irradiated baboons. Journal of Clinical Investigation, 81, 951 955.
  • 10
    Brecher, M.E., Sims, L., Schmitz, J., Shea, T., Bentley, S.A. (1996) North American multi-center study on flow cytometric enumeration of CD34+ hematopoietic stem cells. Journal of Hematotherapy, 5, 227 236.
  • 11
    Bregni, M., Magni, M., Siena, S., Di Nicola, M., Bonadonna, G., Gianni, A.M. (1992) Human peripheral blood hemopoietic progenitors are optimal targets of retroviral-mediated gene transfer. Blood, 80, 1418 1422.
  • 12
    Brugger, W., Henschler, R., Heimfeld, S. (1994) Positively selected autologous blood CD34+ cells and unseparated peripheral blood progenitor cells mediate identical haemopoietic engraftment after high dose VP16, ifosamide, carboplatin and epirubicin. Blood, 84, 1421 1426.
  • 13
    Chang, A. & Ma, D. (1996) The influence of flow cytometric gating strategy on the standardization of CD34+ cell quantitation: an Australian multi-centre study. Journal of Hematotherapy, 5, 605 616.
  • 14
    Chin-Yee, I., Keeney, M., Anderson, L., Nayar, R., Sutherland, D.R. (1997a) Current status of CD34+ cell analysis by flow cytometry: the ISHAGE Guidelines. Clinical Immunology Newsletter, 17, 21 29.
  • 15
    Chin-Yee, I., Keeney, M., Anderson, L., Sutherland, D.R. (1997b) Quality assurance of stem cell enumeration by flow cytometry. Cytometry (Communications in Clinical Cytometry), 30, 1 8.
  • 16
    Connelly, M.C., Knight, M., Giorgi, J.V., Kagan, J., Landay, A.L., Parker, J.W., Page, E., Spino, C., Wilkening, C., Mercolino, T. (1995) Standardization of absolute CD4+; lymphocyte counts across laboratories: an evaluation of the Ortho CytoronAbsolute flow cytometry system on normal donors. Cytometry, 22, 200 210.
  • 17
    Dreger, P., Haferlach, T., Eckstein, V., Jacobs, S., Suttorp, M., Löffler, H., Muller Ruchholz, W., Schmitz, N. (1994) G-CSF mobilised peripheral blood progenitor cells for allogeneic transplantation: safety, kinetics of mobilization, and composition of the graft. British Journal of Haematology, 87, 609 613.
  • 18
    Edwards, B.S., Altobelli, K.K., Nolla, H.A., Harper, D.A., Hoffman, R.R. (1989) Comprehensive quality assessment approach for flow cytometric immunophenotyping of human lymphocytes. Cytometry, 10, 433 441.
  • 19
    Gee, A.P. & Lamb, L.S. (1994) Preparation of samples for flow cytometric analysis: recommendations from the ISHAGE course in San Jose. Hematopoietic Stem Cells: The Mulhouse Manual (ed. by E. Wunder, H. Sovalat, P. R. Henon and S. Serke), p. 67. AlphaMed Press, Dayton.
  • 20
    Goguel, A.F., Crainic, K., Ducailar, A., Ouin, M. (1993) Interlaboratory quality assessment of lymphocyte phenotyping. Etalonorme 1990–1992 surveys. Biology of the Cell, 78, 79 84.
  • 21
    Gratama, J.W., Kraan, J., Levering, W., Van Bockstaele, D.R., Rijkers, G.T., Van Der Schoot, C.E. (1997) Analysis of variation in results of CD34+ hematopoietic progenitor cell enumeration in a multicenter study. Cytometry, 30, 109 117.
  • 22
    Gratama, J.W., Orfao, A., Barnett, D., Brando, B., Huber, A., Janossy, G., Johnsen, H.E., Keeney, M., Marti, G.E., Preijers, F., Rothe, G., Serke, S., Sutherland, D.R., Van den Schoot, C.E., Schmitz, G., Papa, S. (1998) Flow cytometric enumeration of CD34+ hematopoietic stem and progenitor cells. Cytometry, (in press).
  • 23
    Gratwohl, Baldomero, H. & Hermans, J. (1996) Haemopoietic precursor cell transplant activity in Europe, 1994. Bone Marrow Transplantation, 17, 137 148.
  • 24
    Haas, R., Mohle, R., Fruehauf, S., Goldschmidt, H., Witt, B., Flentje, M., Wannenmacher, M., Hunstein, W. (1994) Patient characteristic associated with successful mobilizing and autografting of peripheral blood progenitor cells in malignant melanoma. Blood, 83, 3787 3794.
  • 25
    Homburger, H.A., Rosenstock, W., Paxton, H., Paton, M.L., Landay, A.L. (1993) Assessment of interlaboratory variability of immunophenotyping: results of the College of American Pathologists Flow Cytometry Survey. Annals of the New York Academy of Sciences, 677, 43 49.
  • 26
    Janossy, G., Bikoue, A., Tilling, R.E., Reilly, J.T., Granger, V., Barnett, D. (1998) Stabilized cellular immunofluorescent analysis (SCIFA): a new concept for quantitative flow cytometry in routine immunohaematology. Cytometry, 31, (Suppl. 9), 145 146.
  • 27
    Johnsen, H.E. (1995) Report from a Nordic Workshop on CD34+ cell analysis: Technical recommendations for progenitor cell enumeration in leukapheresis from multiple myeloma patients. Journal of Hematotherapy, 4, 21 28.
  • 28
    Johnsen, H.E. (1997) Toward a worldwide standard for CD34+ enumeration? Journal of Hematotherapy, 6, 83 84.
  • 29
    Johnsen, H.E. & Knudsen, L.M. (1996) Nordic flow cytometry standards for CD34+ cell enumeration in blood and leukapheresis products: report from the second Nordic workshop. Journal of Hematotherapy, 5, 237 245.
  • 30
    Keeney, M., Chin-Yee, I., Weir, K., Popma, J., Nayar, R., Sutherland, D.R. (1998) Single platform flow cytometric absolute CD34+ cell counts based on the ISHAGE guidelines. Cytometry (Communications in Clinical Cytometry), 34, 61 70.
  • 31
    Krause, D., Fackler, M.J., Civin, C.I., May, W.S. (1996) CD34: structure, biology, and clinical utility. Blood, 87, 1 13.
  • 32
    Lowdell, M.A. & Bainbridge, D.R. (1996) External quality assurance for CD34 cell enumeration: results of a preliminary national trial. Bone Marrow Transplantation, 17, 849 853.
  • 33
    Lumley, M.A., McDonald, D.F., Czarnecka, H.M., Billingham, L.J., Milligan, D.W. (1996) Quality assurance of CD34+ cell estimation in leukapheresis products. Bone Marrow Transplantation, 18, 791 796.
  • 34
    Macey, M.G., McCarthy, D.A., Van Agthoven, A.J., Newland, A.C. (1997) How should CD34+ cells be analysed? A study of three classes of antibody and five leucocyte preparation procedures. Journal of Immunological Methods, 204, 175 188.
  • 35
    McCarthy, D.A., Macey, M.G., Cahill, M.R., Newland, A.C. (1994) Effect of fixation on quantification of the expression of leucocyte function-associated surface antigens. Cytometry, 17, 39 49.
  • 36
    Mercolino, T.J., Connelly, M.C., Meyer, E.J., Knight, M.D., Parker, J.W., Stelzer, G.T., DeChirico, G. (1995) Immunologic differentiation of absolute count with an integrated flow cytometric system: a new concept for absolute T cell subset determinations. Cytometry, 22, 48 59.
  • 37
    Paxton, H., Kidd, P., Landay, A., Giorgi, J., Flomenberg, N., Walker, E., Valentine, F., Fahey, J., Gelman, R. (1989) Results of the flow cytometry ACTG quality control program: analysis and findings. Clinical Immunology and Immunopathology, 52, 68 84.
  • 38
    Robinson, G., Morgan, L., Evans, M., McDermott, S., Pereira, S., Wansbrough-Jones, M., Griffin, G. (1992) Effect of type of haematology analyser on CD4 count. Lancet, 340, 485.
  • 39
    Ross, A.A., Miller, G.W., Moss, T.J., Kahn, D.G., Warner, N.E., Sweet, D.L., Louie, K.G., Schneidermann, E., Pecora, A.L., Meagher, R.C., Herzig, R.H., Collins, R.H., Fay, J.W. (1995) Immunocytochemical detection of tumour cells in bone marrow and peripheral blood stem cell collections from patients with ovarian cancer. Bone Marrow Transplantation, 15, 929 933.
  • 40
    Russell, N.H., Gratwohl, A., Schmitz, N. (1996) The place of blood stem cells in allogeneic transplantation. British Journal of Haematology, 93, 747 753.
  • 41
    Schonwald, E. & Jilch, R. (1994) Report of initial experiences in establishing a regional multicenter evaluation of lymphocyte typing with flow cytometry. [German]. Wiener Klinische Wochenschrift, 106, 247 249.
  • 42
    Siena, S., Bregni, M., Brando, B., Belli, N., Ravagnani, F., Gandola, L., Stern, A.C., Lansdorp, P.M., Bonadonna, G., Gianni, A.M. (1991) Flow cytometry for the clinical estimation of circulating hematopoietic progenitors for autologous transplantation in cancer patients. Blood, 77, 400 409.
  • 43
    Strauss, K., Hannet, I., Engel, S., Shiba, A., Ward, D., Ullery, S., Jinguji, M.G., Valinsky, J., Barnett, D., Orfao, A., Kestens, L. (1996) Performance evaluation of FACSCount: a dedicated system for clinical cellular analysis. Cytometry, 26, 52 59.
  • 44
    Sutherland, D.R., Anderson, L., Keeney, M., Nayar, R., Chin-Yee, I. (1996) The ISHAGE Guidelines for CD34+ cell determination by flow cytometry. Journal of Hematotherapy, 5, 213 226.
  • 45
    Sutherland, D.R., Anderson, L., Keeney, M., Nayar, R., Chin-Yee, I. (1997) Re: Toward a worldwide standard for CD34+ enumeration. Journal of Hematotherapy, 6, 85 89.
  • 46
    Sutherland, D.R. & Keating, A. (1992) The CD34 antigen: structure, biology and potential clinical applications. Journal of Hematotherapy, 1, 115 129.
  • 47
    Sutherland, D.R., Marsh, J.C.W., Davidson, J. (1992) Differential sensitivity of CD34 epitopes to cleavage by Pasteurella haemolytica glycoprotease: implications for purification of CD34-positive progenitor cells. Experimental Hematology, 20, 590 599.
  • 48
    Verwer, B.J.H. & Ward, D.M. (1997) An automated classification algorithm for ProCount flow cytometric acquisition and analysis. Journal of Hematotherapy, 6, 169.
  • 49
    Wunder, E., Sovalat, H., Fritsch, G., Silvestri, F., Henon, P.R., Serke, S. (1992) Report on the European Workshop on Peripheral Blood Stem Cell Determination and Standardization, Mulhouse, France. Journal of Hematotherapy, 1, 131 142.