SEARCH

SEARCH BY CITATION

References

  • 1
    Clarke, K., Taberner, D.A., Thomson, J.M., Morris, J.A., Poller, L. (1992) Assessment of value of calibrated lyophilized plasmas to determine International Sensitivity Index for coagulometers. Journal of Clinical Pathology, 45, 58 60.
  • 2
    Clauss, A. (1957) Gerinnungsphysiologische Schnellmethode zur Bestimmung des Fibrinogens. Acta Haematologica, 17, 237 246.
  • 3
    Craig, S., Stevenson, K.J., Dufty, J.M., Taberner, D.A. (1997) Local INR correction: justification for a simplified approach. Clinical Pathology, 50, 783 789.
  • 4
    D'Angelo, A., Seveso, M.P., D'Angelo, S.V., Gilardoni, F., Macagni, A., Manotti, C. (1989) Comparison of two automated coagulometers and the manual tilt tube method for the determination of prothrombin time. American Journal of Clinical Pathology, 92 , 321 328.
  • 5
    Houbouyan, L. & Goguel, A.F. (1997) Long-term French experience in INR standardization by a procedure using plasma calibrants. American Journal of Clinical Pathology, 108, 83 89.
  • 6
    Hubbard, A.R., Margetts, S.M.L., Barrowcliffe, T.W. (1997) INR determination using calibrated reference plasmas. British Journal of Haematology, 98, 74 78.
  • 7
    Kirkwood, T.B.L. (1983) Calibration of reference thromboplastins and standardisation of the prothrombin time ratio. Thrombosis and Haemostasis, 49, 238 244.
  • 8
    Poller, L., Barrowcliffe, T.W., Van Den Besselaar, A.M.H.P., Jespersen, J., Tripodi, A., Houghton, D. (1996) European Concerted Action on Anticoagulation (ECAA). The multicentre calibration of rabbit and human ECAA reference thromboplastins. Thrombosis and Haemostasis, 76, 977 982.
  • 9
    Poller, L., Barrowcliffe, T.W., Van Den Besselaar, A.M.H.P., Jespersen, J., Tripodi, A., Houghton, D. (1997) European Concerted Action on Anticoagulation. A simplified statistical method for local INR using linear regression. British Journal of Haematology, 98, 640 647.
  • 10
    Poller, L., Barrowcliffe, T.W., Van Den Besselaar, A.M.H.P., Jespersen, J., Tripodi, A., Houghton, D. (1998a) European Concerted Action on Anticoagulation (ECAA). Minimum lyophilized plasma requirement for ISI calibration. American Journal of Clinical Pathology, 109, 196 204.
  • 11
    Poller, L., Thomson, J.M., Taberner, D.A. (1989) Effect of automation on the prothrombin time test in NEQAS surveys. Journal of Clinical Pathology, 42, 97 100.
  • 12
    Poller, L., Triplett, D.A., Hirsh, J., Carroll, J., Clarke, K. (1995a) The value of plasma calibrants in correcting coagulometer effects on International Normalized Ratios: an international multicenter study. American Journal of Clinical Pathology, 103, 358 365.
  • 13
    Poller, L., Triplett, D.A., Hirsh, J., Carroll, J., Clarke, K. (1995b) A comparison of lyophilized artificially depleted plasmas and lyophilized plasmas from patients receiving warfarin in correcting for coagulometer effects on International Normalized Ratios. American Journal of Clinical Pathology, 103, 366 371.
  • 14
    Poller, L., Van Den Besselaar, A.M.H.P., Jespersen, J., Tripodi, A., Houghton, D. (1998b) European Concerted Action on Anticoagulation (ECAA). A comparison of artificially depleted, lyophilized coumarin and fresh coumarin plasmas in thromboplastin calibration. British Journal of Haematology, 101, 462 467.
  • 15
    Ray, M.J. & Smith, I.R. (1990) The dependence of the International Sensitivity Index on the coagulometer used to perform the prothrombin time. Thrombosis and Haemostasis, 63, 424 429.
  • 16
    Stevenson, K.J., Craig, S., Dufty, J.M.K., Taberner, D.A. (1997) System ISI calibration: a universally applicable scheme is possible only when coumarin plasma calibrants are used. British Journal of Haematology, 96, 435 441.
  • 17
    Thomson, J.M. (1970) A Practical Guide to Blood Coagulation and Haemostasis, pp. 178 179. Churchill Livingstone, London.
  • 18
    Tripodi, A., Chantarangul, V., Akkawat, B., Clerici, M., Mannucci, P.M. (1995) A partial factor V deficiency in anticoagulated lyophilized plasmas was identified as a cause of the International Normalized Ratio discrepancy in an External Quality Assessment Scheme. Thrombosis Research, 78, 283.
  • 19
    Van Der Velde, E.A. (1984) Orthogonal regression equation. Thromboplastin Calibration and Oral Anticoagulation (ed. by A. M. H. P. van den Besselaar, H. R. Gralnick and S. M. Lewis), pp. 25 40. Martinus Nijhoff, Boston.
  • 20
    Van Rijn, J.L.M.L., Schmidt Nico, A., Rutten, W. (1989) Correction of instrument and reagent based differences in determination of the international normalised ratio (INR) for monitoring anticoagulant therapy. Clinical Chemistry, 355, 840 843.
  • 21
    W.H.O. Expert Committee on Biological Standardisation (1983) 33rd Report. WHO Technical Series, 687, 81 105.