Get access

Nitrogenase activity in cyanobacteria measured by the acetylene reduction assay: a comparison between batch incubation and on-line monitoring

Authors

  • Marc Staal,

    Corresponding author
    1. Department of Marine Microbiology, NIOO-Center for Marine and Coastal Ecology, PO Box 140, 4400 AC Yerseke, The Netherlands.
      *For correspondence. E-mail staal@cemo.nioo.knaw.nl; Tel. (+31) 113 577 479; Fax (+31) 113 573 616.
    Search for more papers by this author
  • Sacco te Lintel-Hekkert,

    1. Life Science Trace Gas Facility, Department of Molecular and Laser Physics, University of Nijmegen, Toernooiveld, 6525 ED Nijmegen, The Netherlands.
    Search for more papers by this author
  • Frans Harren,

    1. Life Science Trace Gas Facility, Department of Molecular and Laser Physics, University of Nijmegen, Toernooiveld, 6525 ED Nijmegen, The Netherlands.
    Search for more papers by this author
  • Lucas Stal

    1. Department of Marine Microbiology, NIOO-Center for Marine and Coastal Ecology, PO Box 140, 4400 AC Yerseke, The Netherlands.
    Search for more papers by this author

*For correspondence. E-mail staal@cemo.nioo.knaw.nl; Tel. (+31) 113 577 479; Fax (+31) 113 573 616.

Abstract

A new on-line method for measuring acetylene reduction is described. It consists of a gas-flow cell connected to an electronic gas-mixing system and an automatic sample loop in the gas chromatograph. Alternatively, ethylene can be determined by using laser-based trace gas detection. The laser-based trace gas detection technique achieves a detection limit that is three orders of magnitude better than gas chromatography. We have applied the on-line method to the measurement of nitrogen fixation in a culture of the heterocystous cyanobacterium Nodularia spumigena and compared it with conventional batch-type incubations. Incubation of N. spumigena in the gas-flow cell resulted in very short response times with a steady-state flux of ethylene obtained within 2 min. Nitrogenase was shown to respond immediately to changes in light and oxygen. Monitoring of nitrogenase activity could be continued for several hours without having a negative impact on nitrogen fixation rates in N. spumigena. This was not the case in batch incubations, in which changes in nitrogenase activities were recorded during incubations, probably as a result of varying oxygen concentrations. It was therefore concluded that the on-line method is superior to batch incubations when rates of nitrogenase activity are to be measured. The method is suitable for natural samples (water or sediment).

Get access to the full text of this article

Ancillary