Comparison of a saliva wetness tester and a moisture-checking device in patients with maxillary obturator prostheses

Authors

  • Mamoru Murakami,

    1. Department of Oral and Maxillofacial Prosthodontics, Field of Oral and Maxillofacial Rehabilitation, Course for Advanced Therapeutics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
    Search for more papers by this author
  • Yasuhiro Nishi,

    Corresponding author
    1. Department of Oral and Maxillofacial Prosthodontics, Field of Oral and Maxillofacial Rehabilitation, Course for Advanced Therapeutics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
    • Correspondence to:

      Yasuhiro Nishi, Department of Oral and Maxillofacial Prosthodontics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan.

      Tel.: +81-99-275-6222

      Fax: +81-99-275-6228

      E-mail: shar@dent.kagoshima-u.ac.jp

    Search for more papers by this author
  • Yuji Kamashita,

    1. Denture Prosthodontics Restoration, Advanced Dentistry Center, Kagoshima University Medical and Dental Hospital, Kagoshima, Japan
    Search for more papers by this author
  • Eiichi Nagaoka

    1. Department of Oral and Maxillofacial Prosthodontics, Field of Oral and Maxillofacial Rehabilitation, Course for Advanced Therapeutics, Kagoshima University Graduate School of Medical and Dental Sciences, Kagoshima, Japan
    2. Denture Prosthodontics Restoration, Advanced Dentistry Center, Kagoshima University Medical and Dental Hospital, Kagoshima, Japan
    Search for more papers by this author

Abstract

Objective

Examination of dry mouth in postoperative oral tumour patients should ideally be performed simply and quickly at the chair side. Moisture-checking devices and saliva wetness testers are available for such moisture measurement. Previous studies have reported that moisture-checking devices are useful to examine dry mouth in patients with maxillary obturator prostheses. However, because the measurement principles of saliva wetness testers differ from those of moisture-checking devices, diagnosis by the two devices may result in diagnostic disagreement. The purpose of the present study was to compare the usefulness of a saliva wetness tester with a moisture-checking device for patients with maxillary obturator prostheses.

Methods

Oral moisture was measured with a moisture-checking device and a saliva wetness tester in 30 subjects with maxillary obturator prostheses. These measurements were performed five times at the lingual mucosa, and mean values of each measurement were calculated. The reference value for moisture measurements with the moisture-checking device was 29%, and that with the saliva wetness tester was 3 mm. Subjects were classified as having dry mouth when their moisture measurements were less than the reference values.

Results

The diagnostic results of the saliva wetness tester were in agreement with those of the moisture-checking device. The respective moisture measurements showed a significant positive correlation (r = 0.88, p < 0.01).

Conclusion

The results of the present study demonstrate that saliva wetness testers are as useful as moisture-checking devices to examine dry mouth in patients with maxillary obturator prostheses.