SEARCH

SEARCH BY CITATION

References

  • 1
    Felbinger TW, Reuter DA, Eltzschig HK, Moerstedt K, Goedje O, Goetz AE. Comparison of pulmonary arterial thermodilution and arterial pulse contour analysis: Evaluation of a new algorithm. Journal of Clinical Anesthesia 2002; 14: 2296301.
  • 2
    Barry BN, Mallick A, Bodenham AR, Vuceciv M. Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients. Critical Care 1997; 2: 714.
  • 3
    Moxon D, Pinder M, Van Heerden PV, Parsons RW. Clinical evaluation of the HemoSonic monitor in cardiac surgical patients in the ICU. Anaesthesia and Intensive Care 2003; 31: 40811.
  • 4
    Iijima T. Another alternative for cardiac output measurement: pulse dye-densitometry. Critical Care Medicine 1999; 27: 1634.
  • 5
    Imai T, Takahashi K, Goto F, Morishita Y. Measurement of blood concentration of indocyanine green pulse dye densitometry: comparison with the conventional spectrophotometric method. Journal of Clinical Monitoring and Computing 1998; 14: 47784.
  • 6
    Kasuya Y, Kawai H, Yamamoto T, Dohi S. Comparison of pulse dye densitometry and thermodilution method in cardiac output measurement. Masui 1998; 47: 7568.
  • 7
    Iijima T, Aoyagi T, Iwao Y, et al. Cardiac output and circulating blood Volume analysis by pulse dye-densitometry. Journal of Clinical Monitoring and Computing 1997; 13: 819.
  • 8
    Sha K, Schimokawa M, Morii M, Kikumoto K, Inoue S, Kishi K. Optimal dose of indocyanine-green injected from the peripheral vein in cardiac output measurement by pulse dye-densitometry. Masui 2000; 49: 1726.
  • 9
    Hofer CK, Bühlmann S, Klaghofer R, Genoni M, Zollinger A. Pulsed dye densitometry with different sensor types for cardiac output measurements after cardiac surgery: a comparison with the thermodilution technique. Acta Anaesthesiologica Scandinavica 2004; 48: 6537.
  • 10
    Fukuda H, Kawamoto M, Yuge O. A comparison of finger and nose probes in pulse dye-densitometry measurements of cardiac output, blood volume and mean transit time. Masui 2001; 50: 13516.
  • 11
    Bühlmann S, Hofer CK, Genoni M, Zollinger A. Comparison of dye pulse densitometry with the thermodilution technique for cardiac output measurement after cardiac surgery. Part II. Transcutaneous signal detection by a nose probe. European Journal of Anaesthesiology 2002: 34: A139.
  • 12
    Imai T, Takahashi K, Fukura H, Morishita Y. Measurement of cardiac output by pulse dye densitometry using indocyanine green: a comparison with the thermodilution method. Anesthesiology 1997; 87: 81622.
  • 13
    Bremer F, Schiele A, Tschaikoswky A. Cardiac output measurement by pulse dye densitometry: a comparison with the Fick's principle and thermodilution method. Intensive Care Medicine 2002; 28: 399405.
  • 14
    Sakka SG, Reinhard K, Wegscheider K, Meier-Hellmann A. Comparison of cardiac output and circulatory blood volumes by transpulmonary thermo-dye-dilution and transcutaneous indocyanine green measurement in critically ill patients. Chest 2002; 121: 55965.
  • 15
    Schmid ER, Schmidlin D, Tornic M, Seifert B. Continuous thermodilution cardiac output: clinical validation against a reference technique of known accuracy. Intensive Care Medicine 1999; 25: 16672.
  • 16
    Watanabe Y, Kumon K. Assessment by pulse dye-densitometry indocyanine green (ICG) clearance test of hepatic function of patients before cardiac surgery: its value as a predictor of serious postoperative liver dysfunction. Journal of Cardiothoracic and Vascular Anesthesia 1999; 13: 299303.
  • 17
    Kanaya N, Nakayama M, Fujita S, Namiki A. Comparison of the effects of sevoflurane, isoflurane and halothane on indocyanine green clearance. British Journal of Anaesthesia 1995; 74: 1647.
  • 18
    Aono J, Furuno K, Ueda W, Manbe M. ICG-disappearance rate during sevoflurane- or neurolept anesthesia. Masui 1994; 43: 8947.
  • 19
    Levett JM, Replogle RL. Thermodilution cardiac output: a critical analysis and review of the literature. Journal of Surgical Research 1979; 6: 392404.
  • 20
    Burns E, Triger DR, Tucker GT, Bax ND. Indocyanine green elimination in patients with liver disease and in normal subjects. Clinical Science 1991; 80: 15560.
  • 21
    Haruna M, Kumon K, Yahagi N, Watanabe Y, Ishida Y, Kobayashi N, Aoyagi T. Blood volume measurement at the bedside using ICG pulse spectrophotometry. Anesthesiology 1998; 89: 13228.
  • 22
    Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 30710.
  • 23
    Critchley LAH, Critchley JAJ. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. Journal of Clinical Monitoring and Computing 1999; 15: 8591.
  • 24
    Tibballs J, Hochmann M, Osborne A, Carter B. Accuracy of the BoMED NCCOM3 bioimpedance cardiac output monitor during induced hypotension: an experimental study in dogs. Anaesthesia and Intensive Care 1992; 20: 32631.
  • 25
    Fox IH, Brooker LGS, Heseltine DW, Wood EH. A new dye for continuous recording of dilution curves in whole blood independent of variations in blood oxygen saturation. Circulation 1956; 7: 936.
  • 26
    Fox IH, Wood EH. Indocyanine green: physical and physiological properties. Mayo Clinic Proceedings 1960; 35: 73244.
  • 27
    Landsman ML, Kwant G, Mook GA, Zijlstra WG. Light absorbing properties, stability, and spectral stabilization of indocyanine green. Journal of Applied Physiology 1976; 40: 57583.
  • 28
    Shrewsbury RP, Lewis LM, Oliver SR, Womble CL. Effect of moderate hemodilution with Fluosol-DA or normal saline on indocyanine green and (+)-propranolol kinetics. Journal of Pharmacy and Pharmacology 1987; 39: 5928.