The fullPIERS (Pre-eclampsia Integrated Estimate of RiSk) model is a promising tool for the prediction of adverse outcomes in pre-eclampsia, developed using the worst values for predictor variables measured within 48 hours of admission. We reassessed the performance of fullPIERS using predictor variables obtained within 6 and 24 hours of admission, and found that the stratification capacity, calibration ability, and classification accuracy of the model remained high. The fullPIERS model is accurate as a rule-in test for adverse maternal outcome, with a likelihood ratio of 14.8 (95% CI 9.1–24.1) or 17.5 (95% CI 11.7–26.3) based on 6- and 24-hour data, respectively, for the women identified to be at highest risk (predicted probability ≥30%).