SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Cremer M. Ueber die direkte ableitung der aktionsstrome des menschlichen herzens vom oesophagus und uber das elek-trokardiogramm des fotus. Muenchener Med Wochenschr. 1906; 53:81113.
  • 2
    Benson DW, Dunnigan A., Benditt DG, Schneider SP. Transesophageal cardiac pacing: history, application, technique. Clin Prog Pacing Electrophysiol. 1984; 2:36072.
  • 3
    Roelandt JRTC, Sutherland GR. Oesophageal echocardiography. Br Heart J. 1988; 60:13.
  • 4
    Whipple GH, Penton GB. Transesophageal ventricular defibrillation [abstract]. Clin Res Proc. 1956; 4:105.
  • 5
    Guyton AC, Satterfield J. Factors concerned in electrical defibrillation of the heart, particularly through the unopened chest. Am J Physiol. 1951; 167:817.
  • 6
    Kouwenhoven WB. The development of the defibrillator. Ann Intern Med. 1969; 71:44958.
  • 7
    Croal S., Anderson JMcC, Allen JD. Electrical defibrillation of the canine ventricle using oesophageal and precordial electrodes [abstract]. Ir J Med Sci. 1990; 159:28.
  • 8
    McKeown PP, Khan MM, Croal S., Allen JD, Anderson J., Adgey AAJ. Electrocardiographic recording, atrial pacing, and defibrillation in the course of electrophysiologic studies using the esophagus. Coron Artery Dis. 1992; 3:38391.
  • 9
    McKeown PP, Croal S., Allen JD, Anderson J., Adgey AAJ. Transesophageal cardioversion. Am Heart J. 1993; 125: 396404.
  • 10
    Geddes LA. Characteristics of defibril-lating electrodes and living tissue. Proceedings of the Cardiac Defibrillation Conference, Purdue University, 1975; 4553.
  • 11
    Waldo AL, Akhtar M., Brugada P., et al. NASPE policy statement: the minimally appropriate electrophysiologic study for the assessment of patients with documented sustained monomorphic ventricular tachycardia. PACE Pacing Clin Electrophysiol. 1985; 8:91822.
  • 12
    Khosla T., Lowe CR. Indices of obesity derived from body weight and height. Br J Prev Soc Med. 1967; 21:1228.
  • 13
    Brown WH. A study of the esophageal lead in clinical electrocardiography. Part I. The application of the esophageal lead to the human subject with observations on the Ta-wave, extrasystoles and bundle-branch block. Am Heart J. 1936; 12: 145.
  • 14
    Brown WH. A study of the esophageal lead in clinical electrocardiography. Part II. An electrocardiographic study of auricular disorders in the human subject by means of the esophageal lead. Am Heart J. 1936; 12:30738.
  • 15
    Arzbaecher R. A pill electrode for the study of cardiac arrhythmia. Med In-strum. 1978; 12:27781.
  • 16
    Shafiroff BGP, Linder J. Effects of external electrical pacemaker stimuli on the human heart. J Thorac Surg. 1957; 33: 54450.
  • 17
    Gallagher JJ, Smith WM, Kerr CR, et al. Esophageal pacing: a diagnostic and therapeutic tool. Circulation. 1982; 65: 33641.
  • 18
    Burack B., Furman S. Transesophageal cardiac pacing. Am J Cardiol. 1969; 23:46972.
  • 19
    Andersen HR, Pless P. Transesophageal pacing. PACE Pacing Clin Electrophysiol. 1983; 6:6749.
  • 20
    McEneaney D., Adgey J., Anderson J. Non-invasive atrial and pacing using an esothoracic pacing system [abstract]. Br Heart J. 1993; 69:60.
  • 21
    McNally EM, Meyer EC, Langendorf R. Elective countershock in unanesthetized patients with use of an esophageal electrode. Circulation. 1966; 33:1247.
  • 22
    Fields J., Shachtman J., Craig SD, Berkovits BV, Roger A. Special electrode device for trans-esophageal cardioversion. Digest 7th Int Conf Med Biol Eng. Stockholm, 1967; 77.
  • 23
    Lukoseviciute AJ, Peculiene IR. Transesophageal cardioversion of resistant atrial arrhythmias. Resuscitation. 1980; 8:15965.
  • 24
    Dalzell GWN, Anderson J., Adgey AAJ. Factors determining success and energy requirements for cardioversion of atrial fibrillation. Q J Med. 1991; 78:8595.
  • 25
    Geddes LA, Baker LE. The specific resistance of biological material—a compendium of data for the biomedical engineer and physiologist. Med Biol Eng. 1967; 5:27193.
  • 26
    Kerber RE, Grayzel J., Hoyt R., Marcus M., Kennedy J. Transthoracic resistance in human defibrillation: influence of body weight, chest size, serial shocks, paddle size, and paddle contact pressure. Circulation. 1981; 63:67682.
  • 27
    Dalzell GWN, Cunningham SR, Magee H., Anderson J., Adgey AAJ. Human transthoracic resistance—role of skin fold thickness and body fat. PACE Pacing Clin Electrophysiol [abstract]. 1988; 11:856.
  • 28
    Kerber RE, Hoyt R., Aronson A., Kieso R., Melton J. Evaluation of a new defibrillation pathway—the tongue-epigas trie route. I. Experimental studies in dogs J Am Coll Cardiol. 1983; 2:96672.