SEARCH

SEARCH BY CITATION

References

  • Ahearn, D. G., S. A. Crow, R. B. Simmons, D. L. Price, J. A. Noble, S. K. Mishra & D. L. Pierson: Fungal colonization of fiberglass insulation in the air distribution system of a multi-story office building: VOC production and possible relationship to a sick building syndrome. J. Ind. Microbiol. 1996, 16, 280285.
  • Alarie, Y.: Sensory irritation by airborne chemicals. CRC Crit. Rev. Toxicol. 1973, 2, 299363.
  • Alarie, Y., M. Schaper, G. D. Nielsen & M. H. Abraham: Estimating the sensory irritating potency of airborne nonreactive volatile organic chemicals and their mixtures. SAR QASR Environ. Res. 1996, 5, 151165.
  • ASTM: Standard test method for estimating sensory irritancy of airborne chemicals. Designation: E981–84. American Society for Testing and Materials, Philadelphia 1984.
  • Bata, A., B. Harrach, K. Ujszászi, A. Kis-Tamás & R. Lásztity: Macrocyclic trichothecene toxins produced by Stachybotrys atra strains isolated in Middle Europe. Appl. Environ. Microbiol. 1985, 49, 678681.
  • Bjurman, J. & J. Kristensson: Volatile production by Aspergillus versicolor as a possible cause of odor in houses affected by fungi. Mycopathologia 1992, 118, 173178.
  • Bjurman, J., E. Nordstrand & J. Kristensson: Growth-phase-related production of potential volatile - organic tracer compounds by moulds on wood. Indoor Air 1997, 7, 27.
  • Boylstein, L. A., S. J. Anderson, R. D. Thompson & Y. Alarie: Characterization of the effects of an airborne mixture of chemicals on the respiratory tract and smoothing polynomial spline analysis of the data. Arch. Toxicol. 1995, 69, 579589.
  • Boylstein, L. A., J. Luo, M. F. Stock & Y. Alarie: An attempt to define a just detectable effect for airborne chemicals on the respiratory tract in mice. Arch. Toxicol. 1996, 70, 567578.
  • Breum, N. O., B. H. Nielsen, E. M. Nielsen, U. Midtgaard & O. M. Poulsen: Dustiness of compostable waste: a methodological approach to quantify the potential of waste to generate airborne micro-organisms and endotoxin. Waste Manage. Res. 1997, 15, 169187.
  • Börjesson, T., U. Stöllman & J. Schnürer: Volatile metabolites produced by six fungal species compared with other indicators of fungal growth on cereal grains. Appl. Environ. Microbiol. 1992, 58, 25992605.
  • Cometto-Muñiz, J. E. & W. S. Cain: Agonistic sensory effects of airborne chemicals in mixtures: odor, nasal pungency, and eye irritation. Percept. Psychophys. 1997, 59, 665674.
  • Creasia, D. A., J. D. Thurman, L. J. Jones, M. L. Nealley, C. G. York, R. W. Wannemacher & D. L. Bunner: Acute inhalation toxicity of T-2 mycotoxin in mice. Fund. Appl. Toxicol. 1987, 8, 230235.
  • Croft, W. A., B. B. Jarvis & C. S. Yatawara: Airborne outbreak of trichothecene toxicosis. Atmos. Environ. 1986, 20, 549552.
  • Dales, R. E., R. Burnett & H. Zwanenburg: Adverse health effects among adults exposed to home dampness and molds. Amer. Rev. Respir. Dis. 1991, 143, 505509.
  • Devos, M., F. Patte, J. Rouault, P. Laffort & L. J. van Gemert: Standardized human olfactory thresholds. IRL Press, Oxford 1990.
  • Dewey, S., H. Sagunski, U. Palmgren & B. Wildeboer: Mikrobielle flügtige organische Verbindungen in der Raumluft: Ein neuer diagnostischer Ansatz bei Feuchten und verschimmelten Wohnräumen Zbl. Hyg. 1995, 197, 504515.
  • Dudek, B. R., T. A. Kaempfe, C. L. Bechtel, J. E. Mueller & R. G. Orth: Potential of 13 carpet-associated chemicals to cause sensory irritation at ambient conditions. The Toxicologist 1997, 36, no. 1, part 2, 328329.
  • El-Maghraby, O. M. O., G. A. Bean, B. B. Jarvis & M. B. Aboul-Nasr: Macrocyclic trichothecenes produced by Stachybotrys isolated from Egypt and Eastern Europe. Mycopathologia 1991, 113, 109115.
  • Gravesen, S., J. C. Frisvad & R. A. Samson: Microfungi. Munksgaard, Copenhagen, 1994.
  • Hansen, L. F., G. D. Nielsen, J. Tøttrup, A. Abildgaard, O. F. D. Jensen, M. K. Hansen & O. Nielsen: Biological determination of emission of irritants from paint and lacquer. Indoor Air 1991, 1, 95110.
  • Haschek, W. M., M. R. Boyd, P. J. Hakkinen, C. S. Owenby & H. Witschi: Acute inhalation toxicity of 3-methylfuran in the mouse: pathology, cell kinetics, and respiratory rate effects. Toxicol. Appl. Pharmacol. 1984, 72, 124133.
  • Hendry, K. M. & E. C. Cole: A review of mycotoxins in indoor air. J. Toxicol. Environ. Health 1993, 38, 183198.
  • Husman, T.: Health effects of indoor-air microorganisms. Scand. J. Work. Environ. Health 1996, 22, 513.
  • Jarvis, B. B., J. Salemme & A. Morais: Stachybotrys toxins. 1. Nat. Toxins 1995, 3, 1016.
  • Jensen, B. & P. O. Wolkoff: VOCBASE version 2. National Institute of Occupational Health, Copenhagen 1996.
  • Johanning, E., R. Biagini, D. Hull, P. Morey, B. Jarvis & P. Landsbergis: Health and immunology study following exposure to toxigenic fungi (Stachybotrys chartarum) in a water-damaged office environment. Int. Arch. Occup. Environ. Health 1996, 68, 207218.
  • Kristiansen, U., L. Hansen, G. D. Nielsen & E. Hoist: Sensory irritation and pulmonary irritation of cumene and n-propanol: mechanisms of receptor activation and desensitization. Acta Pharmacol. et toxicol. 1986, 59, 6072.
  • Kristiansen, U. & G. D. Nielsen: Activation of the sensory irritant receptor by C7-C11 n-alkanes. Arch. Toxicol. 1988, 61, 419425.
  • Kristiansen, U., A. M. Vinggaard & G. D. Nielsen: The effects of n-butanol vapour on respiratory rate and tidal volume. Arch. Toxicol. 1988, 61, 229236.
  • Larsen, F. O., L. H. R. Christensen, P. Clementsen, S. Gravesen, P. S. Skov & S. Norn: Microfungi in indoor air are able to trigger histamine release by non-IgE-mediated mechanisms. Inflamm. Res. 1996, 45(suppl. 1), S23S24.
  • Li, C-S. & L-Y. Hsu: Home dampness and childhood respiratory symptoms in a subtropical climate. Arch. Environ. Health 1996, 51, 4246.
  • Li, C-S., C-W. Hsu & C-H. Lu: Dampness and respiratory symptoms among workers in daycare centers in a subtropical climate. Arch. Environ. Health 1997, 52, 6871.
  • Matthews, T. G., C. V. Thompson, D. L. Wilson, A. R. Hawthorn & D. T. Mage: Air velocities inside domestic environments: an important parameter in the study of indoor air quality and climate. Environ. Int. 1989, 15, 545550.
  • Nakamura, K., M. F. Refojo, D. V. Crabtree, J. Pastor & F.-L. Leong: Ocular toxicity of low-molecular-weight components of silicone and fluorosilicone oils. Invest. Ophthalmol. Vis. Sci. 1991, 32, 30073020.
  • Nielsen, E. M., B. H. Nielsen & N. O. Breum: Occupational bioaerosol exposure during collection of household waste. Ann. Agri. Environ. Med. 1995, 2, 5359.
  • Nielsen, G. D.: Mechanisms of activation of the sensory irritant receptor by airborne chemicals. CRC Crit. Rev. Toxicol. 1991, 21, 183208.
  • Nielsen, G. D. & Y. Alarie: Animal assays for upper airway irritation. Screening of materials and structure-activity relations. Ann. NY Acad. Sci. 1992, 641, 164175.
  • Nielsen, G. D., M. Hammer & L. F. Hansen: Chemical and biological evaluation of building material emissions. III. Screening of a low-emitting fibrous acoustic insulation material. Indoor Air 1997a, 7, 3340.
  • Nielsen, G. D., L. F. Hansen, M. Hammer, K. V. Vejrup & P. Wolkoff: Chemical and biological evaluation of building material emissions. I. A screening procedure based on a closed emisson system. Indoor Air 1997b, 7, 816.
  • Nielsen, G. D., L. F. Hansen & P. Wolkoff: Chemical and biological evaluation of building material emissions. II. Approaches for setting indoor air standards or guidelines for chemicals. Indoor Air 1997c, 7, 1732.
  • Nielsen, G. D., S. H. Petersen, A. M. Vinggaard, L. F. Hansen & P. Wolkoff: Ventilation, CO2 production, and CO2 exposure effects in conscious, restrained CF-1 mice. Pharmacology & Toxicology 1993, 72, 163168.
  • Nielsen, K. F., U. Thrane, T. O. Larsen, P. A. Nielsen & S. Gravesen: Production of mycotoxins on artificially inoculated building materials. Int. Biodeterior. Biodegrad. 1998, in press.
  • Nikulin, M., A.-L. Pasanen, M. Tuomainen, S. Berg, P. Parikka & E.-L. Hinitikka: Stachybotrys atra growth and toxin production in some building materials and fodder under different relative humidities. Appl. Environ. Microbiol. 1994, 60, 34213424.
  • Nikulin, M., K. Reijula, B. B. Jarvis & E.-L. Hintikka: Experimental lung mycotoxicosis in mice induced by Stachybotrys atra. Int. J. Exp. Pathol. 1996, 77, 213218.
  • Nikulin, M., K. Reijula, B. B. Jarvis, P. Veijalainen & E.-L. Hintikka: Effects of intranasal exposure to spores of Stachybotrys atra in mice. Fund. Appl. Toxicol. 1997, 35, 182188.
  • Pasanen, A.-L., M. Nikulin, M. Tuomainen, S. Berg, P. Parikka, & E.-L. Hintikka: Laboratory experiments on membrane filter sampling of airborne mycotoxins produced by Stachybotrys atra corda. Atmos. Environ. 1993, 27A, 913.
  • Pasanen, P., A. Korpi, P. Kallikoski & A.-L. Pasanen: Growth and volatile metabolite production of Aspergillus versicolor in house dust. Environ. Int. 1997, 23, 425432.
  • Raabe, O. G., M. A. Al-Bayati, S. V. Teague & A. Rasolt: Regional deposition of inhaled monodisperse coarse and fine aerosol particles in small laboratory animals. Ann. Occup. Hyg. 1988, 32(suppl. 1), 5363.
  • Rao, C. Y., H. A. Burge & J. C. S. Chang: Review of quantitative standards and guidelines for fungi in indoor air. J. Air Waste Manag. Assoc. 1996, 46, 899908.
  • Reynolds, S. J., A. J. Streifel & C. E. McJilton: Elevated airborne concentrations of fungi in residential and office environments. Am. Ind. Hyg. Assoc. J. 1990, 51, 601604.
  • Routsalainen, R., N. Jaakkola & J. J. K. Jaakkola: Dampness and molds in day-care centers as an occupational health problem. Int. Arch. Occup. Environ. Health 1995, 66, 369374.
  • Smid, T., E. Schokkin, J. S. M. Boleij & D. Heederik: Enumeration of viable fungi in occupational environments: a comparison of samplers and media. Amer. Ind. Hyg. Assoc. J. 1989, 50, 235239.
  • Smith, J. E., J. G. Anderson, C. W. Lewis & Y. M. Murad: Cytotoxic fungal spores in the indoor atmosphere of the damp domestic environment. FEMS Microbiol. Lett. 1992, 100, 337344.
  • Soheilian, M., G. A. Peyman, T. Moritera & H. Wafapoor: Experimental retinal tolerance to very low viscosity silicone oil (100 cs) as a vitreous substitute compared to higher viscosity silicone oil (5000 cs). Int. Ophthalmol. 1995, 19, 5761.
  • Sorenson, W. G., D. G. Frazer, B. B. Jarvis, J. Simpson & V. A. Robinson: Trichothecene mycotoxins in aerosolized conidia of Stachybotrys atra. Appl. Environ. Microbiol. 1987, 53, 13701375.
  • Vijayaraghavan, R., M. Schaper, R. Thompson, M. S. Stock & Y. Alarie: Characteristic modifications of the breathing pattern of mice to evaluate the effects of airborne chemicals on the respiratory tract. Arch. Toxicol. 1993, 67, 478490.
  • Vijayaraghavan, R., M. Schaper, R. Thompson, M. S. Stock, L. A. Boylstein, J. E. Luo & Y. Alarie: Computer assisted recognition and quantitation of the effects of airborne chemicals acting at different areas of the respiratory tract in mice. Arch. Toxicol. 1994, 68, 490499.
  • Waegemaekers, M., N. van Wageningen, B. Brunekreef & J. S. M. Boleij: Respiratory symptoms in damp homes. A pilot study. Allergy 1989, 44, 192198.
  • Wilkins, K. & K. Larsen: Variation of volatile organic compound patterns of mold species from damp buildings. Chemosphere 1995, 31, 32253236.