SEARCH

SEARCH BY CITATION

References

  • 1
    Ganter MT, Hofer CK: Coagulation monitoring: current techniques and clinical use of viscoelastic point-of-care coagulation devices. Anesth Analg 2008; 106:13661375
  • 2
    Tieu BH, Holcomb JB, Schreiber MA: Coagulopathy: its pathophysiology and treatment in the injured patient. World J Surg 2007; 31:10551065
  • 3
    Kozek-Langenecker S: Management of massive operative blood loss. Minerva Anestesiol 2007; 73:401415
  • 4
    Hertfelder HJ, Bos M, Weber D, Winkler K, Hanfland P, Preusse CJ: Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting. Semin Thromb Hemost 2005; 31:426440
  • 5
    Luddington RJ: Thrombelastography/thromboelastometry. Clin Lab Haematol 2005; 27:8190
  • 6
    Fries D, Krismer A, Klingler A, Streif W, Klima G, Wenzel V, Haas T, Innerhofer P: Effect of fibrinogen on reversal of dilutional coagulopathy: a porcine model. Br J Anaesth 2005; 95:172177
  • 7
    Hiippala ST, Myllyla GJ, Vahtera EM: Hemostatic factors and replacement of major blood loss with plasma-poor red cell concentrates. Anesth Analg 1995; 81:360365
  • 8
    Hiippala ST: Dextran and hydroxyethyl starch interfere with fibrinogen assays. Blood Coagul Fibrinolysis 1995; 6:743746
  • 9
    Palareti G, Maccaferri M, Manotti C, Tripodi A, Chantarangkul V, Rodeghiero F, Ruggeri M, Mannucci PM: Fibrinogen assays: a collaborative study of six different methods. C.I.S.M.E.L. Comitato Italiano per la Standardizzazione dei Metodi in Ematologia e Laboratorio. Clin Chem 1991; 37:714719
  • 10
    Rumley A, Woodward M, Hoffmeister A, Koenig W, Lowe GD: Comparison of plasma fibrinogen by Clauss, prothrombin time-derived, and immunonephelometric assays in a general population: implications for risk stratification by thirds of fibrinogen. Blood Coagul Fibrinolysis 2003; 14:197201
  • 11
    Von Clauss A: Rapid physiological coagulation method in determination of fibrinogen. Acta Haematol 1957; 17:237246
  • 12
    Lang T, Von Depka M: Possibilities and limitations of thrombelastometry/-graphy. Hamostaseologie 2006; 26:S20S29
  • 13
    Lang T, Bauters A, Braun SL, Potzsch B, Von Pape KW, Kolde HJ, Lakner M: Multi-centre investigation on reference ranges for ROTEM thromboelastometry. Blood Coagul Fibrinolysis 2005; 16:301310
  • 14
    Weber CF, Jambor C, Marquardt M, Gorlinger K, Zwissler B: Thrombelastometric detection of factor XIII deficiency. Anaesthesist 2008; 57:487490
  • 15
    Spiel AO, Mayr FB, Firbas C, Quehenberger P, Jilma B: Validation of rotation thrombelastography in a model of systemic activation of fibrinolysis and coagulation in humans. J Thromb Haemost 2006; 4:411416
  • 16
    Cammerer U, Dietrich W, Rampf T, Braun SL, Richter JA: The predictive value of modified computerized thromboelastography and platelet function analysis for postoperative blood loss in routine cardiac surgery. Anesth Analg 2003; 96: 5157
  • 17
    Reinhofer M, Brauer M, Franke U, Barz D, Marx G, Losche W: The value of rotation thromboelastometry to monitor disturbed perioperative haemostasis and bleeding risk in patients with cardiopulmonary bypass. Blood Coagul Fibrinolysis 2008; 19:212219
  • 18
    Ferraris VA, Ferraris SP, Saha SP, Hessel EA, Haan CK, Royston BD, Bridges CR, Higgins RS, Despotis G, Brown JR, Spiess BD, Shore-Lesserson L, Stafford-Smith M, Mazer CD, Nett-Guerrero E, Hill SE, Body S: Perioperative blood transfusion and blood conservation in cardiac surgery: the Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists clinical practice guideline. Ann Thorac Surg 2007; 83:S27S86
  • 19
    Anderson L, Quasim I, Soutar R, Steven M, Macfie A, Korte W: An audit of red cell and blood product use after the institution of thromboelastometry in a cardiac intensive care unit. Transfus Med 2006; 16:3139
  • 20
    Avidan MS, Alcock EL, Da FJ, Ponte J, Desai JB, Despotis GJ, Hunt BJ: Comparison of structured use of routine laboratory tests or near-patient assessment with clinical judgement in the management of bleeding after cardiac surgery. Br J Anaesth 2004; 92:178186
  • 21
    Miller BE, Guzzetta NA, Tosone SR, Levy JH: Rapid evaluation of coagulopathies after cardiopulmonary bypass in children using modified thromboelastography. Anesth Analg 2000; 90:13241330
  • 22
    Shore-Lesserson L, Manspeizer HE, DePerio M, Francis S, Vela-Cantos F, Ergin MA: Thromboelastography-guided transfusion algorithm reduces transfusions in complex cardiac surgery. Anesth Analg 1999; 88:312319
  • 23
    Royston D, Von KS: Reduced haemostatic factor transfusion using heparinase-modified thrombelastography during cardiopulmonary bypass. Br J Anaesth 2001; 86:575578
  • 24
    Spalding GJ, Hartrumpf M, Sierig T, Oesberg N, Kirschke CG, Albes JM: Cost reduction of perioperative coagulation management in cardiac surgery: value of “bedside” thrombelastography (ROTEM). Eur J Cardiothorac Surg 2007; 31:10521057
  • 25
    Coakley M, Reddy K, Mackie I, Mallett S: Transfusion triggers in orthotopic liver transplantation: a comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests. J Cardiothorac Vasc Anesth 2006; 20:548553
  • 26
    Gorlinger K: Coagulation management during liver transplantation. Hamostaseologie 2006; 26:S64S76
  • 27
    Herbstreit F, Winter EM, Peters J, Hartmann M: Monitoring of haemostasis in liver transplantation: comparison of laboratory based and point of care tests. Anaesthesia 2010; 65:4449
  • 28
    Daudel F, Kessler U, Folly H, Lienert JS, Takala J, Jakob SM: Thromboelastometry for the assessment of coagulation abnormalities in early and established adult sepsis: a prospective cohort study. Crit Care 2009; 13:R42
  • 29
    Fries D, Innerhofer P, Schobersberger W: Time for changing coagulation management in trauma-related massive bleeding. Curr Opin Anaesthesiol 2009; 22:267274
  • 30
    Huissoud C, Carrabin N, Benchaib M, Fontaine O, Levrat A, Massignon D, Touzet S, Rudigoz RC, Berland M: Coagulation assessment by rotation thrombelastometry in normal pregnancy. Thromb Haemost 2009; 101:755761
  • 31
    Levrat A, Gros A, Rugeri L, Inaba K, Floccard B, Negrier C, David JS: Evaluation of rotation thrombelastography for the diagnosis of hyperfibrinolysis in trauma patients. Br J Anaesth 2008; 100:792797
  • 32
    Schochl H, Frietsch T, Pavelka M, Jambor C: Hyperfibrinolysis after major trauma: differential diagnosis of lysis patterns and prognostic value of thrombelastometry. J Trauma 2009; 67:125131
  • 33
    Doyle S, O’Brien P, Murphy K, Fleming C, O’Donnell J: Coagulation factor content of solvent/detergent plasma compared with fresh frozen plasma. Blood Coagul Fibrinolysis 2003; 14:283287
  • 34
    Stanworth SJ, Brunskill SJ, Hyde CJ, McClelland DB, Murphy MF: Is fresh frozen plasma clinically effective? A systematic review of randomized controlled trials Br J Haematol 2004; 126:139152
  • 35
    Dara SI, Rana R, Afessa B, Moore SB, Gajic O: Fresh frozen plasma transfusion in critically ill medical patients with coagulopathy. Crit Care Med 2005; 33:26672671
  • 36
    Lauzier F, Cook D, Griffith L, Upton J, Crowther M: Fresh frozen plasma transfusion in critically ill patients. Crit Care Med 2007; 35:16551659
  • 37
    Stanworth SJ, Brunskill SJ, Hyde CJ, Murphy MF, McClelland DB: Appraisal of the evidence for the clinical use of FFP and plasma fractions. Best Pract Res Clin Haematol 2006; 19:6782
  • 38
    Stanworth SJ, Hyde CJ, Murphy MF: Evidence for indications of fresh frozen plasma. Transfus Clin Biol 2007; 14:551556
  • 39
    Stainsby D, MacLennan S, Hamilton PJ: Management of massive blood loss: a template guideline. Br J Anaesth 2000; 85:487491
  • 40
    Toth O, Calatzis A, Penz S, Losonczy H, Siess W: Multiple electrode aggregometry: a new device to measure platelet aggregation in whole blood. Thromb Haemost 2006; 96:781788
  • 41
    Cardinal DC, Flower RJ: The electronic aggregometer: a novel device for assessing platelet behavior in blood. J Pharmacol Methods 1980; 3:135158
  • 42
    Rahe-Meyer N, Winterhalter M, Hartmann J, Pattison A, Hecker H, Calatzis A, Solomon C: An evaluation of cyclooxygenase-1 inhibition before coronary artery surgery: aggregometry versus patient self-reporting. Anesth Analg 2008; 107:17911797
  • 43
    Gorlinger K, Jambor C, Dirkmann D, Dusse F, Hanke A, Adamzik M, Hartmann M, Philipp S, Weber AA, Rahe-Meyer N: Platelet function analysis with point-of-care methods. Herz 2008; 33:297305
  • 44
    Ivandic BT, Giannitsis E, Schlick P, Staritz P, Katus HA, Hohlfeld T: Determination of aspirin responsiveness by use of whole blood platelet aggregometry. Clin Chem 2007; 53:614619
  • 45
    Jambor C, Weber CF, Gerhardt K, Dietrich W, Spannagl M, Heindl B, Zwissler B: Whole blood multiple electrode aggregometry is a reliable point-of-care test of aspirin-induced platelet dysfunction. Anesth Analg 2009; 109:2531
  • 46
    Mueller T, Dieplinger B, Poelz W, Calatzis A, Haltmayer M: Utility of whole blood impedance aggregometry for the assessment of clopidogrel action using the novel Multiplate analyzer--comparison with two flow cytometric methods. Thromb Res 2007; 121:249258
  • 47
    Sibbing D, Braun S, Morath T, Mehilli J, Vogt W, Schomig A, Kastrati A, Von BN: Platelet reactivity after clopidogrel treatment assessed with point-of-care analysis and early drug-eluting stent thrombosis. J Am Coll Cardiol 2009; 53:849856
  • 48
    Muller-Schunk S, Linn J, Peters N, Spannagl M, Deisenberg M, Bruckmann H, Mayer TE: Monitoring of clopidogrel-related platelet inhibition: correlation of nonresponse with clinical outcome in supra-aortic stenting. AJNR Am J Neuroradiol 2008; 29:786791
  • 49
    Jambor C, Weber CF, Lau A, Spannagl M, Zwissler B: Multiple electrode aggregometry for ex-vivo detection of the anti-platelet effect of non-opioid analgesic drugs. Thromb Haemost 2009; 101:207209
  • 50
    Scharbert G, Kalb M, Marschalek C, Kozek-Langenecker SA: The effects of test temperature and storage temperature on platelet aggregation: a whole blood in vitro study. Anesth Analg 2006; 102:12801284
  • 51
    Scharbert G, Kalb ML, Essmeister R, Kozek-Langenecker SA: Mild and moderate hypothermia increases platelet aggregation induced by various agonists: a whole blood in vitro study. Platelets 2010; 21:4448
  • 52
    Velik-Salchner C, Maier S, Innerhofer P, Kolbitsch C, Streif W, Mittermayr M, Praxmarer M, Fries D: An assessment of cardiopulmonary bypass-induced changes in platelet function using whole blood and classical light transmission aggregometry: the results of a pilot study. Anesth Analg 2009; 108:17471754
  • 53
    Boldt J, Suttner S, Brosch C, Lehmann A, Mengistu A: Influence on coagulation of a potato-derived hydroxethylstarch (HES 130/0.42) and a maize-derived hydroxethylstarch (HES 130/0.4) in patients undergoing cardiac surgery. Br J Anaesth 2009; 102:191197
  • 54
    Boldt J, Wolf M, Mengistu A: A new plasma-adapted hydroxyethylstarch preparation: in vitro coagulation studies using thrombelastography and whole blood aggregometry. Anesth Analg 2007; 104:425430
  • 55
    Bergmann L, Kienbaum P, Gorlinger K, Peters J: Uneventful removal of an epidural catheter guided by impedance aggregometry in a patient with recent coronary stenting and treated with clopidogrel and acetylsalicylic acid. Reg Anesth Pain Med 2007; 32:354357
  • 56
    Weber CF, Schneider AC, Kirschning T, Hofstetter C, Zacharowski K, Gorlinger K: Therapeutic options for perioperatively acquired platelet dysfunctions. Anaesthesist 2009; 58:931936
  • 57
    Weber CF, Dietrich W, Spannagl M, Hofstetter C, Jambor C: A point-of-care assessment of the effects of desmopressin on impaired platelet function using multiple electrode whole-blood aggregometry in patients after cardiac surgery. Anesth Analg 2010; 110:702707
  • 58
    Rahe-Meyer N, Winterhalter M, Boden A, Froemke C, Piepenbrock S, Calatzis A, Solomon C: Platelet concentrates transfusion in cardiac surgery and platelet function assessment by multiple electrode aggregometry. Acta Anaesthesiol Scand 2009; 53:168175
  • 59
    Poston R, Gu J, Manchio J, Lee A, Brown J, Gammie J, White C, Griffith BP: Platelet function tests predict bleeding and thrombotic events after off-pump coronary bypass grafting. Eur J Cardiothorac Surg 2005; 27:584591
  • 60
    Gorlinger K, Jambor C, Hanke A, Dirkmann D, Adamzik M, Hartmann M, Rahe-Meyer N: Perioperative coagulation management and control of platelet transfusion by point-of-care platelet function analysis. Transfus Med Rev 2007; 34:396411
  • 61
    Mengistu AM, Mayer J, Boldt J, Rohm KD: Whole-blood aggregometry: are there any limits with regard to platelet counts? Acta Anaesthesiol Scand 2009; 53:7276
  • 62
    Seyfert UT, Haubelt H, Vogt A, Hellstern P: Variables influencing Multiplate(TM) whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals. Platelets 2007; 18:199206