SEARCH

SEARCH BY CITATION

References

  • Amino K & Yamakawa R (2000): Long-term results of out-of-the-bag intraocular lens implantation. J Cataract Refract Surg 26: 266270.
  • Bland JM & Altman DG (1986): Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307310.
  • Hayashi K & Hayashi H (2005): Comparison of the stability of 1-piece & 3-piece acrylic intraocular lenses in the lens capsule. J Cataract Refract Surg 31: 337342.
  • Hayashi K, Hayashi H, Nakao F & Hayashi F (2001): Anterior capsule contraction & intraocular lens decentration & tilt after hydrogel lens implantation. Br J Ophthalmol 85: 12941297.
  • Iwase T & Sugiyama K (2006): Investigation of the stability of one-piece acrylic intraocular lenses in cataract surgery & in combined vitrectomy surgery. Br J Ophthalmol 90: 15191523.
  • Koeppl C, Findl O, Kriechbaum K, Buehl W, Wirtitsch M, Menapace R & Drexler W (2003): Postoperative change in effective lens position of a 3-piece acrylic intraocular lens. J Cataract Refract Surg 29: 19741979.
  • Koeppl C, Findl O, Kriechbaum K, Sacu S & Drexler W (2005): Change in IOL position & capsular bag size with an angulated intraocular lens early after cataract surgery. J Cataract Refract Surg 31: 348353.
  • Kurimoto Y, Park M, Sakaue H & Kondo T (1997): Changes in the anterior chamber configuration after small-incision cataract surgery with posterior chamber intraocular lens implantation. Am J Ophthalmol 124: 775780.
  • Landau IM & Laurell CG (1999): Ultrasound biomicroscopy examination of intraocular lens haptic position after phacoemulsification with continuous curvilinear capsulorhexis & extracapsular cataract extraction with linear capsulotomy. Acta Ophthalmol Scand 77: 394396.
  • Loya N, Lichter H, Barash D, Goldenberg-Cohen N, Strassmann E & Weinberger D (2001): Posterior chamber intraocular lens implantation after capsular tear: ultrasound biomicroscopy evaluation. J Cataract Refract Surg 27: 14231427.
  • Marchini G, Pedrotti E, Modesti M, Visentin S & Tosi R (2008): Anterior segment changes during accommodation in eyes with a monofocal intraocular lens: high-frequency ultrasound study. J Cataract Refract Surg 34: 949956.
  • Pavlin CJ, Harasiewicz K & Foster FS (1994): Ultrasound biomicroscopic analysis of haptic position in late-onset, recurrent hyphema after posterior chamber lens implantation. J Cataract Refract Surg 20: 182185.
  • Pereira FA & Cronemberger S (2003): Ultrasound biomicroscopic study of anterior segment changes after phacoemulsification & foldable intraocular lens implantation. Ophthalmology 110: 17991806.
  • Petternel V, Menapace R, Findl O, Kiss B, Wirtitsch M, Rainer G & Drexler W (2004): Effect of optic edge design & haptic angulation on postoperative intraocular lens position change. J Cataract Refract Surg 30: 5257.
  • Taketani F, Matuura T, Yukawa E & Hara Y (2004): Influence of intraocular lens tilt & decentration on wavefront aberrations. J Cataract Refract Surg 30: 21582162.
  • Taketani F, Yukawa E, Ueda T, Sugie Y, Kojima M & Hara Y (2005): Effect of tilt of 2 acrylic intraocular lenses on high-order aberrations. J Cataract Refract Surg 31: 11821186.
  • Tello C, Liebmann J, Potash SD, Cohen H & Ritch R (1994): Measurement of ultrasound biomicroscopy images: intraobserver & interobserver reliability. Invest Ophthalmol Vis Sci 35: 35493552.
  • Ucakhan OO, Ozkan M & Kanpolat A (2009): Anterior chamber parameters measured by the Pentacam CES after uneventful phacoemulsification in normotensive eyes. Acta Ophthalmol 87: 544548.
  • Urbak SF (1999): Ultrasound biomicroscopy. I Accuracy II. & agreement of measurements. Acta Ophthalmol Scand 77: 293297.
  • Urbak SF, Pedersen JK & Thorsen TT (1998): Ultrasound biomicroscopy. Intraobserver II. & interobserver reproducibility of measurements. Acta Ophthalmol Scand 76: 546549.
  • Wirtitsch MG, Findl O, Menapace R, Kriechbaum K, Koeppl C, Buehl W & Drexler W (2004): Effect of haptic design on change in axial lens position after cataract surgery. J Cataract Refract Surg 30: 4551.