Agreement of the Serum Spec fPL™ and 1,2-O-Dilauryl-Rac-Glycero-3-Glutaric Acid-(6′-Methylresorufin) Ester Lipase Assay for the Determination of Serum Lipase in Cats with Suspicion of Pancreatitis

Authors


  • Results of this study were presented in parts as a poster presentation at the American College of Veterinary Internal Medicine Forum in Seattle, WA, June 2013.

Corresponding author: Dr P.H. Kook, Clinic for Small Animal Internal Medicine, Vetsuisse Faculty, University of Zurich, Winterthurerstrasse 260, Zurich 8057, Switzerland; e-mail: peterhendrikkook@gmail.com.

Abstract

Background

Serum lipase activities measured by catalytic assays are claimed to be of limited utility for diagnosing pancreatitis in cats. The Spec fPL assay currently is believed the most sensitive test; however, studies comparing different lipase assays are lacking. 1,2-o-dilauryl-rac-glycero-3-glutaric acid-(6′-methylresorufin) ester (DGGR) assay for the determination of lipase activity has been evaluated in dogs, but no information is available in cats.

Objectives

To investigate the agreement of DGGR-lipase activity and Spec fPL concentration in cats with clinical signs consistent with pancreatitis.

Animals

Two hundred fifty-one client-owned cats.

Methods

DGGR-lipase activity and Spec fPL concentration measured from the same blood sample in cats undergoing investigation for pancreatitis. The agreement between DGGR-lipase and Spec fPL at different cutoffs was assessed using Cohen's kappa coefficient (κ). Sensitivity and specificity were calculated for 31 cases where pancreatic histopathology was available.

Results

DGGR-lipase (cutoff, 26 U/L) and Spec fPL (cutoff, >5.3 μg/L) had a κ of 0.68 (standard error [SE] 0.046). DGGR-lipase (cutoff, 26 U/L) and Spec fPL (cutoff, >3.5 μg/L) had a κ of 0.60 (SE, 0.05). The maximum κ at a Spec fPL cutoff >5.3 μg/L was found when the DGGR-lipase cutoff was set >34 U/L and calculated as 0.755 (SE, 0.042). Sensitivity and specificity were 48% and 63% for DGGR-lipase (cut-off, 26 U/L) and 57% and 63% for Spec fPL (>5.3 μg/L), respectively.

Conclusions and Clinical Importance

Both lipase assays agreed substantially. DGGR assay seems a useful and cost-efficient method compared to the Spec fPL test.