• Please log in or register to access this feature.

SEARCH

SEARCH BY CITATION

References

  • 1
    Sarabanda AV, Bunch TJ, Johnson SB, Mahapatra S, Milton MA, Leite LR, Bruce K, et al. Efficacy and safety of circumferential pulmonary vein isolation using a novel cryothermal balloon ablation system. J Am Coll Cardiol 2005; 46:19021912.
  • 2
    Garan A, Al-Ahmad A, Mihalik T, Cartier C, Capuano L, Holtan D, Song C, et al. Cryoablation of the pulmonary veins using a novel balloon catheter. J Interv Card Electrophysiol 2006; 15:7981.
  • 3
    Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, Kurzidim K, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol 2008; 52:273278.
  • 4
    Kojodjojo P, O'Neill MD, Lim PB, Malcolm-Lawes L, Whinnett ZI, Salukhe TV, Linton NW, et al. Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: Medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart 2010; 96:13791384.
  • 5
    Chun KR, Schmidt B, Metzner A, Tilz R, Zerm T, Köster I, Fürnkranz A, et al. The ‘single big cryoballoon’ technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study. Eur Heart J 2009; 30:699709.
  • 6
    Van Belle Y, Janse P, Theuns D, Szili-Torok T, Jordaens L. One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation. Europace 2008; 10:12711276.
  • 7
    Chierchia GB, de Asmundis C, Namdar M, Westra S, Kuniss M, Sarkozy A, Bayrak F, et al. Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: A feasibility study. Europace 2012; 147:962967.
  • 8
    Chun KR, Fürnkranz A, Metzner A, Schmidt B, Tilz R, Zerm T, Köster I, et al. Cryoballoon pulmonary vein isolation with real-time recordings from the pulmonary veins. J Cardiovasc Electrophysiol 2009; 20:12031210.
  • 9
    Tang M, Kriatselis C, Nedios S, Ye G, Roser M, Fleck E, Gerds-Li JH. A novel cryoballoon technique for mapping and isolating pulmonary veins: A feasibility and efficacy study. J Cardiovasc Electrophysiol 2010; 21:626631.
  • 10
    Dorwarth U, Schmidt M, Wankerl M, Krieg J, Straube F, Hoffmann E. Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success. J Interv Card Electrophysiol 2011; 32:205211.
  • 11
    Schwagten B, DE Greef Y, Acou WJ, Stockman D. An apparent way of achieving proof of pulmonary vein disconnection during cryoballoon ablation. Pacing Clin Electrophysiol 2011 (in press; doi: 10.1111/j.1540-8159.2011.03187.x. [Epub ahead of print]).
  • 12
    Schmidt B, Antz M, Ernst S, Ouyang F, Falk P, Chun JK, Kuck KH. Pulmonary vein isolation by high-intensity focused ultrasound: First-in-man study with a steerable balloon catheter. Heart Rhythm 2007; 4:575584.
  • 13
    Linhart M, Bellmann B, Mittmann-Braun E, Schrickel JW, Bitzen A, Andrié R, Yang A, et al. Comparison of cryoballoon and radiofrequency ablation of pulmonary veins in 40 patients with paroxysmal atrial fibrillation: A case-control study. J Cardiovasc Electrophysiol 2009; 20:13431348.
  • 14
    Siklódy CH, Minners J, Allgeier M, Allgeier HJ, Jander N, Keyl C, Weber R, et al. Pressure-guided cryoballoon isolation of the pulmonary veins for the treatment of paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2010; 21:120125.
  • 15
    Ho SY, Cabrera JA, Tran VH, Farré J, Anderson RH, Sánchez-Quintana D. Architecture of the pulmonary veins: Relevance to radiofrequency ablation. Heart 2001; 86:265270.
  • 16
    Weiss C, Gocht A, Willems S, Hoffmann M, Risius T, Meinertz T. Impact of the distribution and structure of myocardium in the pulmonary veins for radiofrequency ablation of atrial fibrillation. Pacing Clin Electrophysiol 2002; 25:13521356.