A stochastic approach to estimate the uncertainty of dose mapping caused by uncertainties in b-spline registration

Authors

  • Hub Martina,

    1. Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
    Search for more papers by this author
    • Author to whom correspondence should be addressed. Electronic mail: m.hub@dkfz.de

  • Thieke Christian,

    1. Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany and Department of Radiation Oncology, University Clinic Heidelberg, 69120 Heidelberg, Germany
    Search for more papers by this author
  • Kessler Marc L.,

    1. Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan 48109
    Search for more papers by this author
  • Karger Christian P.

    1. Department of Medical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), 69120 Heidelberg, Germany
    Search for more papers by this author

Abstract

Purpose:

In fractionated radiation therapy, image guidance with daily tomographic imaging becomes more and more clinical routine. In principle, this allows for daily computation of the delivered dose and for accumulation of these daily dose distributions to determine the actually delivered total dose to the patient. However, uncertainties in the mapping of the images can translate into errors of the accumulated total dose, depending on the dose gradient. In this work, an approach to estimate the uncertainty of mapping between medical images is proposed that identifies areas bearing a significant risk of inaccurate dose accumulation.

Methods:

This method accounts for the geometric uncertainty of image registration and the heterogeneity of the dose distribution, which is to be mapped. Its performance is demonstrated in context of dose mapping based on b-spline registration. It is based on evaluation of the sensitivity of dose mapping to variations of the b-spline coefficients combined with evaluation of the sensitivity of the registration metric with respect to the variations of the coefficients. It was evaluated based on patient data that was deformed based on a breathing model, where the ground truth of the deformation, and hence the actual true dose mapping error, is known.

Results:

The proposed approach has the potential to distinguish areas of the image where dose mapping is likely to be accurate from other areas of the same image, where a larger uncertainty must be expected.

Conclusions:

An approach to identify areas where dose mapping is likely to be inaccurate was developed and implemented. This method was tested for dose mapping, but it may be applied in context of other mapping tasks as well.