SEARCH

SEARCH BY CITATION

REFERENCES

  • 1
    Genant HK, Grampp S, Gluer CC et al. 1994 Universal standardization for dual X-ray absorptiometry: Patient and phantom cross-calibration results J Bone Miner Res 9:15031514.
  • 2
    Wilson CR, Fogelman I, Blake G et al. 1991 The effect of positioning of dual X-Ray bone densitometry of the proximal femur Bone Miner 12:6376.
  • 3
    Devogelaer JP, Le Thi C, Depresseux G, Nagant de Deuxchaines C, 1990 Reproducibility of bone mass measurements in human volunteers using three DPA and one dual X-ray bone densitometers: Correlation between the instruments. Bath Conference on Osteoporosis and Bone Mineral Measurement, Bath, U.K. British Institute of Radiology, p. 36.
  • 4
    Svendsen OL, Marslew U, Hassager C, Christiansen C 1992 Measurement of bone mineral density of proximal femur by two commercially available dual energy X-ray absorptiometric systems Eur J Nucl Med 19:4146.
  • 5
    Duboeuf F, Braillon P, Chapuy et al. 1991 Bone mineral density of the hip measured with dual energy X-ray absorptiometry in normal elderly women and in patients with hip fracture Osteoporos Int 1:242249.
  • 6
    Orwoll WS, Oviatt BK 1991 Longitudinal precision of dual X-ray absorptiometry in a multicenter study J Bone Miner Res 5:191197.
  • 7
    Estilo MJ, Gluer CC, Faulkner KG, Laval-Jeantet AM, Engelke K, Genant HK 1991 Long-term precision and longitudinal sensitivity in vivo of quantitative computed tomography and dual X-ray absorptiometry J Bone Miner Res 6 (Suppl 1):S107.
  • 8
    Laskey MA, Flexman ME, Barber RW et al. 1991 Comparative performance in vivo and in vivo of Lunar DPX and Hologic QDR-1000 dual X-ray absorptiometers Br J Radiol 64:10231029.
  • 9
    Reginster JY, Deroisy R, Albert A, Sarlet N, Franchimont P, 1991 Long-term precision of quantitative digital radiology, Vol 2. Third International Symposium on Osteoporosis. Copenhagen, Denmark. Osteopress Aps, pp. 876877.
  • 10
    Gluer CC, Steiger P, Selvidge R, Elliesen-Kliefoth K, Hayashi C, Genant HK 1990 Comparative assessment of dual-photon-absorptiometry and dual-energy-radiography Radiology 174:223228.
  • 11
    Mazess RB, Chesnut CH, McClung M, Genant HK 1992 Enhanced precision with dual-energy X-ray absorptiometry Calcif Tissue Int 51:1417.
  • 12
    Pouilles JM, Tremollieres F, Todorovsky N, Ribot C 1991 Precision and sensitivity of dual-energy X-ray absorptiometry in spinal osteoporosis J Bone Miner Res 6:9971002.
  • 13
    Bassett CA 1994 Letters Osteoporos Int 4:283284.
  • 14
    Nevitt MC, Johnell O, Black DM, Ensrud K, Genant HK, Cummings SR, for the Study of Osteoporotic Fractures Research Group 1994 Bone mineral density predicts non-spine fractures in very elderly women Osteoporos Int 4:325331.
  • 15
    Cummings SR, Black DM, Nevitt MC et al. 1993 Bone density at various sites for prediction of hip fractures Lancet 341:7275.
  • 16
    Bendavid EJ, Young KC, Gluer CC, Grampp HK 1992 Frequency and magnitude of analysis errors of bone density results assessed by dual X-ray absorptiometry J Bone Miner Res 7:373382.
  • 17
    Trevisan C, Gandolini GG, Sibilla P, Penotti M, Caraceni MP, Ortolani S 1992 Bone mass measurement by DXA: Influence of analysis procedures and interunit variation J Bone Miner Res 7:373382.
  • 18
    Wahner HW, Looker A, Dunn WL, Walters L, Hauser MF 1993 Precision of bone mineral measurement (BMD) at the proximal femur in a multicenter study using three mobile examination centers (Nhames III) J Bone Miner Res 8 (Suppl 1):S354.
  • 19
    Molczyk L, Dalton K, Fannon P, Wilson M, Gallagher JC 1994 Precision of femoral neck measurement in elderly women J Bone Miner Res 9 (Suppl 1):A354.