A Novel Voltammetric In‐Situ Profiling System for ContinuousReal‐Time Monitoring of Trace Elements in Natural Waters
Abstract
This article describes a novel voltammetric in‐situ profiling system (VIP System) for continuous, real‐time monitoring of trace elements in fresh and seawater down to 500 meter depth. The VIP System has been designed using advanced microprocessor and telemetry technology. The heart of the submersible voltammetric probe is a Hg‐plated Ir‐based microsensor covered with an antifouling gel membrane. This gel integrated microsensor allows direct voltammetric measurements of trace metals in complex media without physical and chemical interferences of the test solution. A detailed description of the system is given and examples of environmental applications are reported for in‐situ trace metal monitoring in oxygen saturated seawater as well as for in‐situ profiling of MnII in anoxic lake water. The results indicate that the VIP System is robust and reliable and that in‐situ measurements of mobile fraction of trace metals can be achieved down to very low concentration levels (ca. 5 ppt).
Number of times cited: 16
- Tomer Noyhouzer and Daniel Mandler, A New Electrochemical Flow Cell for the Remote Sensing of Heavy Metals, Electroanalysis, 25, 1, (109-115), (2012).
- Dawang Guo, Jing Li, Jipei Yuan, Weihong Zhou and Erkang Wang, Nafion Film Immobilized Nano Ag‐Hg Amalgam Glassy Carbon Electrode Used for Simultaneous Determination of Lead, Cadmium and Copper, Electroanalysis, 22, 1, (69-73), (2009).
- Mary‐Lou Tercier‐Waeber, Fabio Confalonieri, Milena Koudelka‐Hep, Jacynthe Dessureault‐Rompré, Flavio Graziottin and Jacques Buffle, Gel‐Integrated Voltammetric Microsensors and Submersible Probes as Reliable Tools for Environmental Trace Metal Analysis and Speciation, Electroanalysis, 20, 3, (240-258), (2007).
- Conrad S. Chapman and Constant M. G. van den Berg, Anodic Stripping Voltammetry Using a Vibrating Electrode, Electroanalysis, 19, 13, (1347-1355), (2007).
- Stéphanie Betelu, Corinne Parat, Nathalie Petrucciani, Alain Castetbon, Laurent Authier and Martine Potin‐Gautier, Semicontinuous Monitoring of Cadmium and Lead with a Screen‐Printed Sensor Modified by a Membrane, Electroanalysis, 19, 2‐3, (399-402), (2007).
- Dirk Ruhlig, Albert Schulte and Wolfgang Schuhmann, An Electrochemical Robotic System for Routine Cathodic Adsorptive Stripping Analysis of Ni2+ Ion Release from Corroding NiTi Shape Memory Alloys, Electroanalysis, 18, 1, (53-58), (2005).
- Stéphane Noël, Mary‐Lou Tercier‐Waeber, Lin Lin, Jacques Buffle, Olivier Guenat and Milena Koudelka‐Hep, Integrated Microanalytical System for Simultaneous Voltammetric Measurements of Free Metal Ion Concentrations in Natural Waters, Electroanalysis, 18, 21, (2061-2069), (2006).
- Øyvind Mikkelsen, Constant M. G. van den Berg and Knut H. Schrøder, Determination of Labile Iron at Low nmol L−1 Levels in Estuarine and Coastal Waters by Anodic Stripping Voltammetry, Electroanalysis, 18, 1, (35-43), (2005).
- Øyvind Mikkelsen, Silje M. Skogvold and Knut H. Schrøder, Continouos Heavy Metal Monitoring System for Application in River and Seawater, Electroanalysis, 17, 5‐6, (431-439), (2005).
- Øyvind Mikkelsen and Knut H. Schrøder, Amalgam Electrodes for Electroanalysis, Electroanalysis, 15, 8, (679-687), (2003).
- Ivanka Pižeta, Gabriel Billon, Jean‐Claude Fischer and Michel Wartel, Solid Microelectrodes for In Situ Voltammetric Measurements, Electroanalysis, 15, 17, (1389-1396), (2003).
- Paolo Ugo, Ligia Maria Moretto and Francesca Vezzà, Ionomer‐Coated Electrodes and Nanoelectrode Ensembles as Electrochemical Environmental Sensors: Recent Advances and Prospects, ChemPhysChem, 3, 11, (917-925), (2002).
- Manoj Kumar Ram, Paolo Bertoncello and C. Nicolini, Langmuir‐Schaefer Films of Processable Poly(o‐ethoxyaniline) Conducting Polymer: Fabrication, Characterization and Application as Sensor for Heavy Metallic Ions, Electroanalysis, 13, 7, (574-581), (2001).
- Christopher M. A. Brett, Valéria A. Alves and Denise A. Fungaro, Nafion‐Coated Mercury Thin Film and Glassy Carbon Electrodes for Electroanalysis: Characterization by Electrochemical Impedance, Electroanalysis, 13, 3, (212-218), (2001).
- Martial Taillefert, George W. Luther and Donald B. Nuzzio, The Application of Electrochemical Tools for In Situ Measurements in Aquatic Systems, Electroanalysis, 12, 6, (401-412), (2000).
- M.‐L. Tercier‐Waeber, J. Pei, J. Buffle, G. C. Fiaccabrino, M. Koudelka‐Hep, G. Riccardi, F. Confalonieri, A. Sina and F. Graziottin, A Novel Voltammetric Probe with Individually Addressable Gel‐Integrated Microsensor Arrays for Real‐Time High Spatial Resolution Concentration Profile Measurements, Electroanalysis, 12, 1, (27-34), (2000).