Volume 40, Issue 4
Research Article

In situ cyclic tests on existing stone masonry walls and strengthening solutions

Alexandre A. Costa

Corresponding Author

E-mail address: aacosta@fe.up.pt

Department of Civil Engineering, Faculty of Engineering, University of Porto, R. Dr. Roberto Frias s/n, 4200‐465 Porto, Portugal

Departamento de Engenharia Civil, Secção de Estruturas, Faculdade de Engenharia da Universidade do Porto, 4200‐465 Porto, PortugalSearch for more papers by this author
António Arêde

Department of Civil Engineering, Faculty of Engineering, University of Porto, R. Dr. Roberto Frias s/n, 4200‐465 Porto, Portugal

Search for more papers by this author
Aníbal Costa

Department of Civil Engineering, University of Aveiro Campus Universitário de Santiago, 3810‐193 Aveiro, Portugal

Search for more papers by this author
Carlos Sousa Oliveira

Department of Civil Engineering and Architecture, Instituto Superior Técnico Avenida Rovisco Pais, 1, 1049‐001 Lisboa, Portugal

Search for more papers by this author
First published: 20 September 2010
Citations: 31

Abstract

The present work reports on an in situ experimental test campaign carried out on abandoned traditional masonry houses after the 9th July 1998 earthquake that seriously hit the Faial island of Azores. For the testing purposes, an experimental test setup was developed based on a self‐equilibrated scheme, which is herein described reporting on the advantages and drawbacks of this in situ test setup.

Five specimens were tested aiming at characterizing the out‐of‐plane behavior of stone masonry walls and strengthening solutions recommended for post‐earthquake interventions. A detailed comparison between solutions' efficiency is presented including a cost vs benefit analysis.

In order to assess the efficiency of the developed test setup for other applications on stone masonry walls, an in‐plane test on an existing URM panel is also presented. Several related issues are discussed, namely the advantages of dealing with the real boundary conditions and the capacity of providing valuable information of the response, as well as a detailed analysis of the obtained results.

The authors believe that this work provides an increase in knowledge on the seismic behavior of the existing masonry constructions, resulting from the development of an in situ test setup and the efficiency quantification of strengthening solutions. Therefore, the work is thought to positively contribute for the preservation of architectural heritage and for its seismic vulnerability reduction. Copyright © 2010 John Wiley & Sons, Ltd.

The full text of this article hosted at iucr.org is unavailable due to technical difficulties.