Measuring precision in bioassays: Rethinking assay validation

Michael P. Fay

Corresponding Author

E-mail address: mfay@niaid.nih.gov

Biostatistics Research Branch, National Institute of Allergy and Infectious Diseases, 5601 Fishers Lane, Room 4B53, MSC 9820, Bethesda, MD 20892 USA

Correspondence

Michael P. Fay, Biostatistics Research Branch, National Institute of Allergy and Infectious Diseases, 5601 Fishers Lane, Room 4B53, MSC 9820, Bethesda, MD 20892, USA.

Email: mfay@niaid.nih.gov

Search for more papers by this author
Michael C. Sachs

Unit of Biostatistics, Institute of Environmental Medicine, Karolinska Institutet Nobels väg 13, 17 177 Stockholm, Sweden

Search for more papers by this author
Kazutoyo Miura

Laboratory of Malaria and Vector Research, National Institute of Allergy and Infectious Diseases, Rockville, MD, USA

Search for more papers by this author
First published: 19 October 2017

Abstract

The m:n:θb procedure is often used for validating an assay for precision, where m levels of an analyte are measured with n replicates at each level, and if all m estimates of coefficient of variation (CV) are less than θb, then the assay is declared validated for precision. The statistical properties of the procedure are unknown so there is no clear statistical statement of precision upon passing. Further, it is unclear how to modify the procedure for relative potency assays in which the constant standard deviation (SD) model fits much better than the traditional constant CV model. We use simple normal error models to show that under constant CV across the m levels, the probability of passing when the CV is θb is about 10% to 20% for some recommended implementations; however, for extreme heterogeniety of CV when the largest CV is θb, the passing probability can be greater than 50%. We derive 100q% upper confidence limits on the CV under constant CV models and derive analogous limits for the SD under a constant SD model. Additionally, for a post‐validation assay output of y, we derive 68.27% confidence intervals on either the mean or log geometric mean of the assay output using either y±s (for the constant SD model) or urn:x-wiley:sim:media:sim7528:sim7528-math-0001 (for the constant CV model), where s and rG are constants that do not depend on y. We demonstrate the methods on a growth inhibition assay used to measure biologic activity of antibodies against the malaria parasite.